Parameter No.32 Level of low battery 

Available settings: 10-50 (10% - 50%) 

Default setting: 20 (20%) 

Parameter size: 1[byte] 

 

Parameter No.41 Enable send central scene notification. 

0 - Disable. 

1 – Enable. 

Default setting: 1 

Parameter size: 1[byte] 

 

Parameter No.42 Setting the duration value of the command switch multilevel. 

Available settings: 0-255 

Default setting: 255 

Parameter size: 1[byte] 

 

Parameter No.43 Enable/disable the buzzer alarm when battery is running low. 

0 - Disable. 

1 –Enable. 

Default setting: 

Parameter size: 1[byte] 

XV. NOTES FOR OTA 

 

With reference to Wake-up operation (VI.WAKE UP) and Z-Wave controller's guidances to do OTA. 

 

 

 

XVI. FCC NOTICE (for USA) 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and 

(2) This device must accept any interference received, including interference that may cause 
undesired operation. 

The  manufacturer  is  not  responsible  for  any  radio  or  TV  interference  caused  by  unauthorized 
modifications or change to  this equipment. Such modifications or change could void the user’s 
authority to operate the equipment. 
 
This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

Summary of Contents for NanoMote One

Page 1: ...h groups many smart nodes such as Plugs Bulbs and Siren The scene may refer to sleep scene movie scene and entertainment scene etc as you created Features 1 Z Wave Plus certified for good compatibilit...

Page 2: ...ment 10 50 0 85 Operational temperature 0 40 Radio protocol Z Wave Radio frequency 868 42MHz EU 908 42MHz US 921 42MHz ANZ Range More than 100m outdoors About 30m indoors depending on building materia...

Page 3: ...INSTALLATION Open the cover Insert battery and close the cover...

Page 4: ...work will act as repeaters regardless of vendor to increase reliability of the network 1 Insert the LIR2450 battery 2 Place the device within the direct range of your Z Wave controller 3 Set the main...

Page 5: ...upported command classes 8 1 The node info frame supports COMMAND_CLASS_ZWAVEPLUS_INFO V2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_SECURITY_2 V1 COMMAND_CLASS_TRANSPORT_SERVICE V2 2 Security Command Su...

Page 6: ...econds the LED light will be solid on in purple Then release the button the LED light will be stay in purple for 2 seconds during this 2 seconds please click the button once it will start to test the...

Page 7: ...ote One sends the central scene notification command and battery report command Group 2 allows NanoMote One sends the basic set command Group 3 allows NanoMote One sends switch multilevel set the mult...

Page 8: ...ups is 5 2 Association allows for direct transmission of control command between devices and takes place without the participation of the main controller XIII BUTTON FUNCTION NanoMote One offers three...

Page 9: ...erence to Wake up operation VI WAKE UP and Z Wave controller s guidances to do OTA XVI FCC NOTICE for USA This device complies with part 15 of the FCC Rules Operation is subject to the following two c...

Page 10: ...installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the...

Reviews: