background image

4

Place the air purifier face up on a 

flat, stable work surface. Open the 

access panel by pressing in latches 

on each side of the unit (Fig 3). 

Disconnect main housing assembly 

from rear housing assembly. 

Separate main housing from rear 

housing. Lift main housing assembly 

away from rear mounting housing 

(Fig 8).

Open access panel and remove 

filter assembly by pulling out on 

top of side edges of frame, then 

lifting.  NOTE:  remove  all  plastic 

wrap from filters (Fig 4).

Remove the six housing screws (Fig 5 & 6) and set aside for re-assembly.

At the location of the two upper 

housing corner screws (Fig 5), insert 

a flat head screwdriver and gently 

twist to release tab as shown in Fig 

7. This will disconnect main housing 

assembly from the rear housing 

assembly.

MOUNTING REAR HOUSING AND MAIN ASSEMBLY

REAR HOUSING INSTALLATION & WIRING

Test the electrical outlet box first to ensure rated power requirements are met before beginning installation. 
Remove air purifier from its shipping carton and remove all packing material. 

Reference rear housing and locate desired mounting location. Again, it is strongly recommended at least 2 mounting anchors for the air purifier be mounted to 

an existing stud. 

Fig 3

Fig 7

Fig 4

Fig 8

Fig 5

Fig 6

Fig 10

Fig 11

Using provided template ensure electrical 

outlet box is located behind cable hole (A) 

in  Rear  Housing  assembly  (Fig  9).  Drill 

holes and place anchors in wall.
If mounting on concrete, cinder block or 

brick type walls route the wires through 

the “punch-out” hole marked (B) in Fig 9.

Check for washers at all mounting 

screw  locations  (Fig  10).  Pull  wires 

from electrical outlet box through 

hole in rear housing. Align housing 

over anchors and securely install all 

mounting screws.

Attach wires from electrical outlet box to wires located inside rear housing using wire nuts.  Match up line (black) and neutral (white) wires (Fig 11).  Make sure 

all connections are made in accordance with federal, state and local codes and regulations. 

A

B

A

B

Fig 9

Summary of Contents for AM IV

Page 1: ...INSTALLATION GUIDE AeraMax PRO Air Quality Control System AM IV Please read instructions carefully before installing unit ...

Page 2: ...lity Control System AM IV 1 Access panel 2 Filters 3 Filter frame 4 Main Assembly 5 Power Switch 6 Access panel latch 7 Access panel lock 8 Rear housing assembly 9 Control panel 10 Filter frame window KEY 1 6 2 7 3 8 9 10 4 5 Fig 1 ...

Page 3: ...s and 2 Flat Head screw drivers not included Wire nuts not included Level not included Mounting template included Fig 2 8 PARTS PROVIDED FOR INSTALLATION PRODUCT INSTALLATION GUIDELINES Americans with Disabilities Act ADA Be sure to follow all ADA guidelines pertaining to Objects protruding into a circulation path For more information visit www ada gov Place the mounting template provided on the w...

Page 4: ... requirements are met before beginning installation Remove air purifier from its shipping carton and remove all packing material Reference rear housing and locate desired mounting location Again it is strongly recommended at least 2 mounting anchors for the air purifier be mounted to an existing stud Fig 3 Fig 7 Fig 4 Fig 8 Fig 5 Fig 6 Fig 10 Fig 11 Using provided template ensure electrical outlet...

Page 5: ...s own weight Open front panel by pressing latches on both sides of unit Allow door to open fully Insert filters IMPORTANT make sure filter detection window is aligned in upper right corner Fig 18 To restrict access to the control panel and filters the unit can be locked To lock insert the key provided and rotate clockwise turn Fig 21 Once the unit is closed re establish power Lights on the control...

Page 6: ...Fellowes Inc 1789 Norwood Ave Itasca Illinois 60143 1095 USA 630 893 1600 1 800 477 7940 Product Support 1 800 945 4545 www aeramaxpro com 2014 Fellowes Inc Part No 408531 Rev B ...

Reviews: