Aercus Instruments™
- WeatherRanger®
49 |
P a g e
7.
Troubleshooting Guide
Problem
Solution
Outdoor sensor
array does not
communicate with
the console
Your sensor array may be out of range
This device is rated at 100m line of sight (no interference, barriers or walls)
but typically you will get 20-40m maximum under most real-world
installations, which includes passing through barriers or walls.
To check that the outdoor sensor is not out of range move the sensor array to
within 3m of the console and follow the test procedure in 3.3.5.
The signal from the outdoor sensor array may be experiencing
interference
Wireless communication is susceptible to interference, distance, walls and
metal barriers. We recommend the following best practices for trouble free
wireless communication:
1.
Electro-Magnetic Interference (EMI). Keep the console at least 1.5m
away from computer monitors and TVs.
2.
Radio Frequency Interference (RFI). Check for sources of
interference (cordless phones, baby monitors, PC monitors etc). If
this is an issue the console and/or sensor array will need to be
relocated.
3.
Metal Barriers. Radio frequency will not pass through metal barriers
such as aluminium siding. If you have metal siding, align the remote
and console through a window to get a clear line of sight.
To check that the outdoor sensor is not encountering interference move the
sensor array to within 3m of the console and follow the reset procedure in
section 3.3.5.
The sensor array may have initiated properly and the data being
registered by the console is invalid
In this case the sensor array and console must be reset as per section 3.3.5
You may need to put fresh batteries in the outdoor sensor array
Check that the batteries in the outdoor sensor array are fresh and fully charged.
Alkaline batteries slow down and freeze in colder temperatures which leads
to signal dropouts so we recommend Lithium batteries in colder climates.
Also avoid rechargeable batteries as many are 1.2V (standard 1.5V required)
and they also leak their peak charge quickly even if they are 1.5V.
Follow the reset procedure in section 3.3.5.