Aercus Instruments™
- WeatherRanger®
50 |
P a g e
Batteries may have been inserted incorrectly
If the batteries were recently replaced, check their polarity to ensure they are
around the correct way as per the icons inside the battery comparted as shown
in Figure 6.
Follow the reset procedure in section 3.3.5.
Console may not have been reset after loss of signal
There may have been a temporary loss of communication due to reception loss
from interference or other location factors, or the batteries may have been
changed in the sensor array and the console has not been reset. In this case
follow the reset procedure in section 3.3.5.
Indoor thermo-
hygrometer does not
communicate with
the console
Your indoor thermo-hygrometer may be out of range
To check that the indoor thermo-hygrometer is not out of range move the
indoor thermo-hygrometer to within 3m of the console, power the console
down (by removing the AC adaptor), wait 10 seconds and then reinsert the
AC adaptor.
The signal from the indoor thermo-hygrometer may be experiencing
interference
Wireless communication is susceptible to interference, distance, walls and
metal barriers. We recommend the following best practices for trouble free
wireless communication.
1.
Electro-Magnetic Interference (EMI). Keep the console at least 1.5m
away from computer monitors and TVs.
2.
Radio Frequency Interference (RFI). Check for sources of
interference (cordless phones, baby monitors, PC monitors etc). If
this is an issue the console and/or thermo-hygrometer will need to be
relocated.
To check that the indoor thermo-hygrometer is not encountering interference
move the thermo-hygrometer to within 3m of the console, power the console
down (by removing the AC adaptor), wait 10 seconds and then reinsert the
AC adaptor.
You may need to put fresh batteries in the indoor thermo-hygrometer
Check that the batteries in the indoor thermo-hygrometer are fresh and fully
charged then power the console down (by removing the AC adaptor), wait 10
seconds and then reinsert the AC adaptor.
Batteries may have been inserted incorrectly
If the batteries were recently replaced, check their polarity to ensure they are
around the correct way as per the icons inside the battery comparted as shown
in Figure 13. Then power the console down (by removing the AC adaptor),
wait 10 seconds and then reinsert the AC adaptor.