WS2083
- 13 -
Press the
ENTER
key to select the following modes, then press the
UP
or
DOWN
key to set the value:
Temperature unit display – C or F.
Outdoor temperature high alarm (press
ON/OFF
to enable/disable). If the alarm is enabled, an
alarm symbol
appears in the display.
Outdoor temperature low alarm (press
ON/OFF
to enable/disable). If the alarm is enabled, an
alarm symbol
appears in the display.
Maximum temperature (since last reset). Resetting the maximum outdoor temperature value -
when both the outdoor temperature value and MAX icon are flashing, hold the
ENTER
key for 3s,
the maximum outdoor temperature value will be reset to the current reading.
Minimum temperature (since last reset). Resetting the minimum outdoor temperature value -
when both the outdoor temperature value and MIN icon are flashing, hold the
ENTER
key for 3s, the
minimum outdoor temperature value will be reset to the current reading.
Outdoor Humidity
Press the
MENU
key eleven times to select the OUTDOOR HUMIDITY section. Procedures and settings are
similar to Indoor Humidity.
Memory
Press the HISTORY key to activate the history data display. Press the
DOWN
key to toggle backwards to see
earlier weather history data together with its time stamp, press the
UP
key to see more recent weather
history. When the history data is displayed, the corresponding time will be displayed in the time section
area (the history data saving interval is preset to 30 minutes).
Pressing the ENTER key again will trigger the memory clear procedure, the word “CLEAR” will be flashing and
the full memory usage icon will be flashing. Pressing and holding the
ENTER
key for 3 seconds will clear the
memory.
Note:
Historical values for some variables are only available once downloaded to PC and will appear as dashes
on the Base Station.
Reset To Factory Default Settings
While in normal display, press and hold the
UP
key for
20 seconds to reset all settings to the manufacturer’s
default settings.