background image

 

WS2083 

- 4 - 

Important Notes

 

 

System Start 

Insert  two  LR6  (AA  size)  batteries  into  the  transmitter.    The  LED  located  in  the  middle  on  the  front  of  the 
transmitter will  illuminate for 4 seconds then  go off.    The transmitter will make an initial data transmission 
and then start the radio controlled time reception routine.    If the time signal can be detected correctly the 
LED will flash 5 times and then remain on for 20s, indicating the time signal has been found correctly 

(note no 

time  signal  is  available  in  Aus/NZ)

.    When reception  of the time  signal is  not  possible the transmitter will 

terminate radio controlled time reception after no more than five minutes and resume normal transmission.   
During the radio controlled time reception period there is no transmission of the outdoor weather data to the 
console. 
 
Insert two LR6 (AA size) batteries into the Base Station.    The console will illuminate for a few seconds with all 
the display segments illuminated for checking.    After this the Base Station will make an initial measurement 
and start to register the transmitter (the Outdoor Reception Signal icon will be turned on). Do not touch the 
Base  Station  before  the  outdoor  data  is  received  or  the  outdoor  sensor  learning  mode  will  be  terminated. 
When the outdoor transmitter has been registered the  Base Station will automatically switch to the normal 
display mode from which all further settings can be adjusted by the user.         
 
If no radio controlled clock (RCC) signal is detected during the initial setup, the transmitter will try once every 
hour  to  get  the  RCC  signal  until  a  signal  is  received.    Once  the  transmitter  receives  the  RCC  signal  it  will 
transmit  the  signal  to  the  Base  Station  which  will  display  the  Radio  Controlled  Clock  icon  and  the  time  will 
synchronise to the RCC time.    If the Base Station does not receive the RCC signal or loses the signal the RCC 
icon will not be displayed. 
 

Positioning 

 

Once you have verified that all of the components of the weather station are working they can be positioned 
in their permanent places. Before permanently mounting make sure that all  the components work properly 
together at their chosen  mounting or standing locations. If there appear to be problems  with the  433 MHz 
radio transmission they can mostly be overcome by moving the mounting locations.       

 

Note:

 The radio communication between the receiver and transmitter in an open field can reach a distance of 

up  to  100m  providing  that  there  are  no  interfering  obstacles  such  as  buildings,  trees,  vehicles,  high 
voltage lines, etc. Radio interferences such as PC screens, radios or TV sets, can in bad cases entirely 
cut off radio communication. Please take this into consideration when choosing standing or mounting 
locations.       

 

Reconnecting Lost Signal 

If  no  outdoor  weather  data  is  displayed  as  a  result  of  loss  of  signal  during  set  up,  mounting,  changing  of 
batteries  in  the  transmitter  or  plugging  or  unplugging  cables,  simply  press  and  hold  the 

DOWN

  key  for  4 

seconds then release.    After this the Base Station will make an initial measurement and start to register the 
transmitter (the Outdoor Reception Signal icon will be turned on). Do not touch the Base Station before the 
outdoor  data  is  received  (this  may  take  several  minutes)  or  the  outdoor  sensor  learning  mode  will  be 
terminated. When the outdoor transmitter has been registered the Base Station will automatically switch to 
the normal display mode from which all further settings can be adjusted by the user.       
 

Note:

 When replacing batteries in the transmitter wait two minutes before re-inserting for a proper reset. 

 
Wind Direction 

On  the  edge  of  the  wind  direction  sensor,  there  are  four  letters  -  “N”,  ”E”,  ”S”  and  “W”  representing  the 
directions North, East, South and West. The wind direction sensor has to be adjusted so that the directions on 
the  sensor  are  matching  your  real  location.  A  permanent  wind  direction  error  will  be  introduced  when  the 

Summary of Contents for WS2083

Page 1: ...WS2083 1 WS2083 PROFESSIONAL WIRELESS WEATHER STATION WITH USB UPLOAD ...

Page 2: ...of incorrect setup please contact our local distributor Greenfrog Scientific www greenfrogscientific co uk and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed Purchased in AUSTRALIA As many issues can be a result of incorrect setup please contact our local distributor Monax Test Weathe...

Page 3: ...PC software package 7 1 8 9 2 10 3 11 4 5 12 13 6 14 1 Time 2 Wind Speed and Direction 3 Barometric Pressure 4 Barometric Trend 5 Indoor Temperature 6 Outdoor Temperature 7 Memory 8 Radio Controlled Clock not applicable Aus NZ 9 Date 10 Rainfall 11 Weather Forecast 12 Indoor Humidity 13 Outdoor Reception Signal 14 Outdoor Humidity Note The presence of the Alarm On icon means that the particular al...

Page 4: ...he signal the RCC icon will not be displayed Positioning Once you have verified that all of the components of the weather station are working they can be positioned in their permanent places Before permanently mounting make sure that all the components work properly together at their chosen mounting or standing locations If there appear to be problems with the 433 MHz radio transmission they can m...

Page 5: ...ich can cause reduced transmission range As such we recommend avoiding the use of rechargeable batteries Note The performance of Alkaline batteries can be significantly reduced in colder environments resulting in loss of signal In this case we recommend the use of Lithium batteries in the thermo hygro sensor Low Battery Indicator The transmitter low battery indicator may illuminate when temperatur...

Page 6: ...WS2083 6 ...

Page 7: ...cable is connected to the wind direction sensor The wind direction sensor s cable is connected to the input marked Wind on the thermo hygro sensor The rain sensor s cable is connected to the input marked Rain on the thermo hygro sensor ...

Page 8: ...l 5 press the UP or DOWN key to set the value Level 1 will produce the faintest appearance level 8 the darkest Press the ENTER key to select the following Time zone 12 24h time display default 12h Manual time setting hours minutes Press the UP or DOWN key to set each value Note The radio controlled clock RCC works off the German DCF77 time signal received across large parts of Europe and the UK so...

Page 9: ...lready determined by the manufacturer it may not be necessary for the majority of users to perform any further basic settings except for Relative Air Pressure see below Changes however can be easily made Wind Press the MENU key three times to select the WIND section the WIND section digits will start flashing Press the UP or DOWN key to shift the display between Average wind speed and Gust default...

Page 10: ...ween mm and inch Rain high alarm press ON OFF to enable disable If the alarm is enabled an alarm symbol appears in the display Maximum rainfall since this was last reset Resetting the maximum rainfall value when both the rain value and MAX icon are flashing hold the ENTER key for 3s the maximum rain value will be reset to the current reading Clearing Total rainfall when both the Total rain value a...

Page 11: ...st automatically over a few days as the unit collects data and begins forecasting Press the ENTER key to select the following modes then press the UP or DOWN key to set the value Set the pressure threshold from 2 4hPa default 2hPa Set the storm threshold from 3 9hPa default 4hPa Note The prediction is for the upcoming 12 24 hours and does not necessarily reflect the current weather situation It ca...

Page 12: ...value and MIN icon are flashing hold the ENTER key for 3s the minimum indoor temperature value will be reset to current reading Indoor Humidity Press the MENU key nine times to select the INDOOR HUMIDITY section the INDOOR HUMIDITY section digits will start flashing Press the UP or DOWN key to change the humidity high alarm press ON OFF to enable disable If the alarm is enabled an alarm symbol app...

Page 13: ...e reset to the current reading Outdoor Humidity Press the MENU key eleven times to select the OUTDOOR HUMIDITY section Procedures and settings are similar to Indoor Humidity Memory Press the HISTORY key to activate the history data display Press the DOWN key to toggle backwards to see earlier weather history data together with its time stamp press the UP key to see more recent weather history When...

Page 14: ...ed and displayed by means of a PC Software Download Note No CD is contained with this unit please download the latest software and Basic Installation Guide by entering the link below into your browser s address bar http www boxcn net CumulusDownload This software allows the display storage and printing of historical data In addition the software allows the data to be uploaded and displayed on a we...

Page 15: ... wind speed appears to be under reporting When set to Average wind speed is measured as the average speed recorded over the 48 second period between transmissions In gusty weather this can appear as though it is under reading Set this to Gust see Wind section above to view the maximum wind speed during each 48 second period My rain gauge is under reporting rainfall or not recording it at all Remov...

Page 16: ...sumption Base station 2XAA 1 5V batteries Remote sensor 2xAA 1 5V batteries Contact Information Purchased in UK EU Please contact our local distributor Greenfrog Scientific www greenfrogscientific co uk and their team will be happy to help Genuine faults can typically be diagnosed without requiring the unit to be returned and replacement parts sent quickly if needed Purchased in AUSTRALIA Please c...

Page 17: ...ve 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request from contact aercusinstruments com COUNTRIES RTTE APPROVAL COMPLIED All EU countries This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their...

Reviews: