AERECO – TF5540_E 7
ENGLISH
FRANÇAIS
V5S
15. Vérifier que le cable est correctement
positionné, puis serrer le serre-cable
Attention : Le cable ne doit pas
être en contact avec les parois du
ventilateur.
15. Check that the wire is correctly
positionned, then grip the wire-gripper.
Be careful: Wire must not be in
contact with inner surfaces of the fan.
x4
10. Ensure the fixing by the mean of 4 screws
(important to ensure air tightness).
11. Prepare the supply connecting:
cut the top of the wire-passing.
12. Set up the wire-passing.
Be careful: please check the air-
tightness of the fan box!
13. Introduce the supply cable in the
wire-passing first then through the wire
gripper inside the fan box.
14. Make the electrical connection according
to the scheme. (N = neutral, Earth, L =
Line)
Connect the wire to the fuse board (1 A
fuse required).
V5S fan must be directly
connected to the fuse board (no other
apparels connected to the line).
Reference version
Premium version
10. L’assurer à l’aide de 4 vis
(important
pour l’étanchéité).
11. Préparer le raccordement de
l’alimentation : découper l’extrémité du
passe-câble.
12. Mettre en place le passe-câble.
Attention : vérifier la bonne
étanchéité du caisson !
13. Introduire le cable d’alimentation dans le
passe-cable puis dans le serre cable à
l’intérieur du caisson.
14. Réaliser la connexion électrique
selon le schéma ci-contre en suivant
les indications : (N = neutre, Terre,
L = Phase)
Raccorder le cable au tableau électrique
(fusible de 1 A requis)
Le V5S doit être
directement connecté au tableau
électrique (aucun autre appareil ne
doit être connecté cette ligne).