18/22
TF5774_C
Aereco S.A.
STARTING UP / OPERATION
▪
Before commissioning, check that the fan is securely attached to its stack and that no
object has been left inside the duct or might interfere with the turbine.
▪
Do not insert anything through the fan.
▪
Check that a bonding jumper is in fact connected to the body.
ST MODE
1)
Power up the appliance. It then starts.
The motor technology used may lead to starting errors.
If this happens, the appliance fails to start and
begins vibrating slightly
. Do not touch anything;
the appliance will itself initiate a starting cycle, until it actually
starts.
2)
To adjust the speed, unscrew the plug on the left.
Take all the usual precautions, because the
appliance is still working. Do not insert
anything through the unit.
Set the speed level, operating the
potentiometer.
Any curve between the minimum (a) and maximum (b) curves presented in the graph below can be obtained. The number of
possible adjustments between these curves is infinite. Intermediary curves are given as examples (not exhaustive).
3)
Screw the plug back. Then put the top cover back on the fan.