Page 5 of 12
Always secure the air dehumidifier
against tipping or uncontrolled rolling
off.
Always place the air dehumidifier on a
level and firm surface.
Procedure:
1.
Install the air dehumidifier.
2.
Ensure that the condensate is always
reliably collected or discharged.
Note:
Free air circulation must be
ensured. Do not cover the air openings.
The free space in front of the air outlet
and the air filter must be at least 1°m.
Operating conditions
Observe Specifications on page 12.
Do not immediately switch on the air
dehumidifier after storing. The device
needs some time to adapt to the room
temperature, in particular in case of
storing below 0°°C.
Electrical connection
Check the following points prior to
electrical connection of the air
dehumidifier:
The mains voltage must be in
conformity with the power supply
values in the Specifications!
Fuse socket and supply system
sufficiently.
Install a residual current circuit
breaker in damp locations or on
building sites!
The coupler of the air dehumidifier
must be suitable for the building
socket outlet.
The socket outlet used must be
grounded.
Connect power cable to power outlet.
Connect condensate drain hose
ATTENTION! Material damage /
insufficient performance due to
improper connection of condensate
drain hose!
Do not bend the hose.
Do not place any objects on the hose.
Check regularly whether condensate is
properly discharged.
Procedure:
1.
Attach condensate drain hose to pipe.
2.
Lay the hose from the air dehumidifier
to an outlet (maximum height
difference: 3 m).
5
Operation and operator
control
Observe chapter 2 "Safety“.
Operating elements
See Fig. 3 on page 1.
Commissioning
Observe chapter 2 "Safety“.
Note:
Before commissioning and after
transport, allow the air dehumidifier to
rest in its final position for about 15
minutes. During this time, the oil
distributed in the cooling system and
churned up by transport flows back into
the compressor.
Procedure:
1.
Connect power cable to power outlet.
2.
Make sure that the drain hose has
been installed correctly and laid
securely into a drain.
3.
Switch air dehumidifier on.