Altitude Diving:

•  Samples ambient pressure every 15 minutes while in DC Surface Mode prior to Dive #1 and for 24 hours after a dive.

•  Automatic adjustment when manually activated from 2,000  to 14,000 feet (610 to 4,270 meters).

•  Above 2,000 feet (610 meters) - recalibrates to adjust Depth readings and adjusts NDLs every 1,000 feet (305 meters)

•  DO NOT use at a different altitude until the unit automatically adjusts to the new altitude.

Low Battery Condition:

• Replace with a 3 volt, CR2430,  Lithium battery.
•  If the battery is replacedwithin 8 seconds, settings and nitrogen and oxygen calculations for repetitive dives are retained.

DECO STOP MAIN

NORM DIVE ALT

SECONDARY

NORM DIVE MAIN

For No Deco Dives

deeper than 30 FT (9

M), a Safety Stop is

displayed upon ascent

to the Stop Depth set.

The Safety Stop is at

the Depth/Time preset.

There is no penalty for

surfacing during the

countdown.

CONDITIONAL VIOLA

(above required Stop)

HIGH PO2

HIGH O2

DIVE COMPUTER MODES

• 

Conservative Factor - when set On, NDLs are reduced to those available at the next 3,000 foot (930 meter) Altitude

• Alternate screens -  Dive Modes have Alternate screens that display Max Depth,  FO2, PO2 (revert to Main after 5 seconds)

• 

Backlight - press Lower/Right button any time while in any dive mode

• 

Alarms - press Upper/Right button to acknowledge/silence Alarms.   Messages scroll until the situations are corrected.

SET MODES

Refer to the Operating Manual for detailed instructions.

• Watch Mode - can set Main Time/Date, Alternate Time, CD TImer, Chronograph start/stop, Daily Alarm

• 

NORM/GAUG Modes - press both Lower/Left and Upper/Right to access Set Groups (F - FO2, A - Alarms, U - Utilities, Serial No.)

• 

Set F (FO2) - FO2 can set be for Air or 21 to 50% O2, FO2 Default

• 

Set A (Alarms) - can set Audible, Depth, EDT, NIBG, DTR, PO2

• 

Set U (Utilities) - can set Wet Activation, Units, No Deco Safety Stop, Conservative Factor, Backlight, Sampling Rate

• 

Change Settings - access Set group, press Lower/Left button to step through items, press Upper/Right to change, press Lower/

Left to save

To access

ALT,

 press

Lower/Left

 < 2 sec

To access

SEC,

 press

Lower/Left

 < 2 sec

NO D SAFETY STOP

FREE SURF MAIN

FREE SURF ALT

FREE DIVE MAIN

FREE DIVE ALT (CDT)

GAUG DIVE MAIN

© 2002 Design, 2006

                            Doc. No. 12-7214-r01 (10/20/06)

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

M

L

A

S

Reviews: