3
1.6 ELECTRICAL REQUIREMENTS
IMPORTANT:
Electrical
wiring,
disconnect
means
and
over
current
protection
are
to
be
supplied
by
the
installer.
Refer
to
the
rating
plate
for
the
maximum
over
current
protection,
minimum
circuit
ampacity,
and
operating
voltage.
See
wiring
diagram.
Install
an
adequately
sized
branch
circuit
disconnect,
per
the
NEC,
within
sight
of
and
readily
accessible
from
heat
pump.
The
cable
or
conduit
and
fittings
connected
from
the
disconnect
to
the
heat
pump
shall
be
rated
for
outdoor
use.
Check
the
heat
pump
rating
plate
and
follow
the
appropriate
instructions
below.
NOTE:
All
wiring
must
be
suitable
for
outdoor
use.
Use
copper
conductors
only.
All
field
wiring
must
be
done
in
accordance
with
National
Electrical
Code
requirements,
applicable
requirements
of
UL,
or
local
codes,
where
applicable.
Electrical
wiring,
disconnect
means
and
over
current
protection
are
to
be
supplied
by
the
installer.
Refer
to
the
rating
plate
for
the
maximum
over
current
protection,
minimum
circuit
ampacity,
and
operating
voltage.
See
wiring
diagram.
current