background image

Set: 40.0°C

44.5

40.0°C

NO PRG

°C

: ON

: OFF

SET. DOMESTIC HOT WATER

DOMESTIC HOT WATER

TIMED PROGRAM OFF

A

B

C

A

B

C

D

D

Italian

o

English

F

rançais

Deuts

ch

Españo

l

Modify DHW status

In the DHW modification window, you can make the following settings: 

A

DHW setpoint:

 press the 

 (increase) and 

 (decrease) keys on the 

same line as the setpoint you want to change. 

B

The timed program active on DHW:

 press the 

 (increase) and 

(decrease) keys on the same line as the setpoint you want to change.

C

Activate the heat pump for DHW production: 

press 

 to choose 

whether to activate or deactivate the heat pump for DHW production

D

Activate the additional heat source (RAS, boiler, etc.) for DHW pro-

duction: 

press 

 to choose whether to activate or deactivate the additional 

heat source (RAS, boiler, etc.) for DHW production.

To move on to the next page, press 

 . To return to the previous page, press 

. The homepage will be restored automatically if 5 minutes elapse with no 

interventions.

DHW MENU

View DHW status

In the DHW menu, you can view or set the data for DHW production (if envis-
aged, and if the DHW management expansion has been correctly installed). 
The information available is as follows:

A

 Temperature in the DHW storage tank

B

 DHW setpoint

C

 The timed program active on DHW:

• 

NO PRG: no timed program active on DHW

• 

PRG 1~5: timed program 1~5 active on DHW

D

 Current status of the loads relating to DHW production. This status is indi-

cated by the colours of the icon components:

• 

1

 : DHW request satisfied and/or not active

• 

2

 : DHW active, using the heat pump only

• 

3

 : DHW active, using the heat pump and the additional heat source 

(RAS, boiler, etc.)

• 

4

 : DHW active, using the additional heat source only (RAS, boiler, etc.)

• 

5

 : anti-legionella cycle in progress

1

2

3

4

5

The keys along the bottom of the window have various functions:

Enabling or disabling DHW:

 press the 

 key (green = enabled; red = dis-

abled)

Accessing the DHW settings page:

 to access the page, press 

To return to the previous page, press the 

 key. The homepage will be re-

stored automatically if 5 minutes elapse with no interventions.

5

Summary of Contents for VMF E6

Page 1: ...User Manual 6795778_00 VMF E6 ...

Page 2: ...uld not be disposed with other household wastes in the entire EU To prevent any harm to the environment or human health cau sed by incorrect disposal of Waste Electrical and Electronic Equipment WEEE please return the device using suitable collection systems or contacting the retailer where the pro duct was purchased For further information please contact the appropriate local authority The incorr...

Page 3: ......

Page 4: ...omponent To make daily use even easier the information and functions available are grouped into a number of simple user friendly menus where you can find the required function or data To access the menu selection page just press the key in the bottom right hand corner of the main page as shown in the figures alongside STRUCTURE OF THE USER MENUS Each user menu contains one function or more which i...

Page 5: ...tpoint values to be used for heating and cooling The pages of this menu are TIMED PROGRAM SETTING SETPOINT SETTING MZC This menu contains the functions for viewing the current status of the zones where MZC units are installed and for modifying the unit operating parameters The pages of this menu are OUTDOOR UNITS This menu contains the functions for setting the parameters of the outdoor units cont...

Page 6: ...il in automatic mode V1 V3 fancoil active at speed V1 V3 AUX auxiliary command active on the selected fancoil L Type of setpoint active on the selected fancoil LOCAL SET setpoint set by the fancoil thermostat PRG OFF fancoil deactivated via the timed program PRG SET 1 setpoint 1 activated on the basis of the timed program PRG SET 2 setpoint 2 activated on the basis of the timed program M Timed pro...

Page 7: ...ss the key to choose which type of heating to activate in the selected zone this option is only available in the case of a radiant system and with correctly wired VMF REB expansions zone heating with the fancoil only zone heating with the fancoil and radiant floor zone heating with the radiant floor only WARNING in cooling mode the system will only activate the fancoil D The timed program active o...

Page 8: ...pse with no interventions DHW MENU View DHW status In the DHW menu you can view or set the data for DHW production if envis aged and if the DHW management expansion has been correctly installed The information available is as follows A Temperature in the DHW storage tank B DHW setpoint C The timed program active on DHW NO PRG no timed program active on DHW PRG 1 5 timed program 1 5 active on DHW D...

Page 9: ...y pressing the key on the lower part of the screen you can copy the time set tings of the current day in ALL the days of the week a drop down window will appear asking for confirmation of the operation To select a different day of the week press the key on the lower part of the screen To return to the previous page press the key The homepage will be restored au tomatically if 5 minutes elapse with...

Page 10: ...of the current day in ALL the days of the week a drop down window will appear asking for confirmation of the operation Select a different timed program by pressing on the lower part of the screen you can select another timed program Select a different day of the timed program to select a different day of the week press the key on the lower part of the screen To move on to the next page press To re...

Page 11: ...ucting D The timed program active on the selected zone press the increase and decrease keys on the same line as the setpoint you want to change By pressing the key on the lower part of the screen you can copy the settings of the page in ALL the system zones a drop down window will ap pear asking for confirmation of the operation To move on to the next page press To return to the previous page pres...

Page 12: ...ode E Indicates that the outdoor unit is producing domestic hot water F Indicates that the additional heater is active on the outdoor unit G Working power of the selected outdoor unit H Processed water temperature I Setpoint active on the outdoor unit L Temperature of the return water M Outside air temperature The keys along the bottom of the window have various functions Navigate the various outd...

Page 13: ... if pressed it sends a reset command to the specific outdoor unit To move on to the next page press To return to the previous page press The homepage will be restored automatically if 5 minutes elapse with no interventions Setting compensation with external air In the window for compensation on the outdoor unit selected always identified by its indicator E you can set A The minimum outside air tem...

Page 14: ...y program is sub divided into 24 bands one for every hour in which you can define the required outdoor unit status by clicking on the key for the relative hour Each press on this key changes the status of the time band portion as explained below Outdoor units DISABLED By pressing the key on the lower part of the screen you can copy the time set tings of the current day in ALL the days of the week ...

Page 15: ...rmec com Aermec se reserva la facultad de aportar en cualquier momento todas las modificaciones consideradas necesarias para la mejora del producto Aermec se reserva el derecho a efectuar cualquier modificación que estime necesaria para mejorar el producto en cualquier momento con la modificación de los datos técnicos ...

Reviews: