Initial Service
The initial service policy is to inspect/service the installation once every (six)-6 months over the first
two-(2) years of operation. Electrical, mechanical, and other applicable components should be
inspected, adjusted, and serviced as detailed in the following check list:
Verify air flow visually
Vigorous Boil
Calm
Absence of sewage odor in aeration chamber
Inspect area around Aero-Stream unit for signs of water puddling.
Inspect/clean cooling grills
Inspect cord for damage
Inspect exposed air line for damage
Inspect effluent filter/clean and clean as needed
Tank Level: _________
Photo of field
Evidence of back-ups
Test alarm
Replace alarm batteries (8 - AA Alkaline)
The owner will be notified in writing about improper system operations that cannot be remedied at the
time of inspection. The owner notification shall include an estimated date of correction.
The diffuser stone can be cleaned with a 3% hydrogen peroxide solution or muriatic acid.
Keep the area around the air compressor free of leaves and other debris. If debris enters the product
through the air intake holes, unplug the product and carefully remove the debris. Restart the system by
plugging power cord into wall outlet.
The effluent filter (if required by local or state code) must be checked six-(6) months after installation
and annually thereafter. Clean the filter by flushing with a hose or replace the filter as required. When
disposing a used filter, place it inside a plastic bag for proper disposal.
WARNING:
The air compressor has no user serviceable parts. The Aero-Alert has no user
serviceable parts other than the batteries. If service is required, call the authorized service provider
listed on the label of the product or Aero-Stream. Attempts to service this product will void warranty
and expose the user to electrical shock which may cause severe injury or death.
Tampering will
void warranty.
Extended Service
The extended service policy commences two-(2) years after installation. The required items for
inspection are the same a required for the initial service period. In the event that a mechanical or
electrical component must undergo off-site repairs, the local authorized representative should maintain
a stock of mechanical and electrical components that may be temporarily installed until repairs are
completed.
Emergency service should be available within 48 hours of a service request.
Summary of Contents for AS1000-2
Page 8: ...8 Aero Stream LLC 2022 102822 Rev H Figure 4 Picture of the AS450 2 System ...
Page 9: ...9 Aero Stream LLC 2022 102822 Rev H Figure 5 Picture of the AS500 2 System ...
Page 10: ...10 Aero Stream LLC 2022 102822 Rev H Figure 6 Picture of the AS600 2 System ...
Page 11: ...11 Aero Stream LLC 2022 102822 Rev H Figure 7 Picture of the AS750 2 System ...
Page 12: ...12 Aero Stream LLC 2022 102822 Rev H Figure 8 Picture of the AS1000 2 System ...
Page 13: ...13 Aero Stream LLC 2022 102822 Rev H Figure 9 Picture of the AS1500 2 System ...