SECTION 3
„AERO” Sp. z 0.0.
EMERGENCY PROCEDURES
AT-3 R100
Page 3-4
SEPTEMBER, 2004
AEROPLANE FLIGHT MANUAL
3.4. Smoke and fire
3.4.1. Engine fire on ground
In case of engine fire on ground take the following steps below:
•
Fuel valve
SHUT
•
Throttle
FULL OPEN
•
Ignition switch
OFF
•
Electrical equipment
OFF
•
Battery and generator
OFF
•
Fire extinguisher
TO BE USED
3.4.2. Fire in flight
In case of engine fire in flight
•
Maintain airspeed
IAS = 120 km/h / 75 mph / 65 kts
•
Fuel valve
PULL SHUT
•
Throttle
FULL OPEN
•
Ignition switch
OFF
•
Battery and generator
OFF
•
Cabin canopy vents
SHUT
•
A side-slip – opposite to the
fire, to blow it out
TO BE PERFORMED
•
When the engine stops
PERFORM EMERGENCY LANDING
CAUTION.
AFTER AN ENGINE FIRE
DO NOT TRY TO RE-START THE ENGINE