background image

INFLATION & ADJUSTMENTS

NOTE: BED MUST BE AT ROOM TEMPERATURE PRIOR TO INFLATING OR IT MAY CAUSE 

AIR LEAKS.
NOTE: PRESSURE CAN VARY DEPENDING ON ROOM TEMPERATURE AND CONSUMER WEIGHT.

1.  Place your rolled-up bed on the floor or other surface free of obstructions or sharp objects.
2.  Make certain the Quick Air Release Valve is closed. If the release valve is open, close it by 

using 2 thumbs to push cover and snap into valve. Be careful to avoid pushing valve cover 

to the right or left as it snaps into the valve opening.

3.  Remove the AC plug and cord from the plastic bag and 

shrink wrap.

4.  Plug into any standard polarized 120 Volt AC electrical outlet. 

North American Electrical rating: 120 VAC 60 Hz 1.5 A.
(Note: 230 VAC product sold outside of North America). This 

product has a polarized attachment plug (one blade is wider 

than the other) as a safety feature. This plug will fit into a 

polarized outlet only one way. If the plug does not fit fully in 

the outlet, reverse the plug. If it still does not fit, contact a 

qualified electrician. Never use with an extension cord unless 

the plug can be fully inserted. Do not attempt to defeat this 

safety feature.

5.  On the Control Wand, press the UP arrow on the switch into the

“INFLATE” position to inflate your bed. Once bed has reached 

desired firmness, return the switch to the off position “O”.

6.  Lie on your bed and use the Control Wand to adjust the firmness 

to your desired level. For a firmer bed, press the UP arrow on the

switch into the “INFLATE” position. For a softer bed, press the 

down arrow “ADJUST” until desired firmness level is attained. 

7.  Once desired firmness is reached, ensure the switch is returned 

to the off position “O”.

USB ChArgINg POrT

1.  Your AeroBed

®

 product includes a USB port built into the 

pump for charging your personal device. Please adhere to the 

following guidelines to ensure proper usage.

2.  In order to charge your personal device 

using the included USB port, the pump must 

remain plugged into any standard polarized 

120VoltAC electrical outlet throughout the 

entire charging cycle.

3.  For your convenience, directly below the 

pump is a black mesh pocket that may be 

used for storing your personal device throughout the charging cycle.

4.  Once your device is fully charged, please disconnect the charging cable from the device 

and from the USB port.

DEFLATION AND STOrAgE

1.  To deflate your bed, open the Quick Release Valve and allow air to expel. 
2.  For the most compact storage, close the valve and use the Control Wand to press the 

DOWN arrow on the switch into the “DEFLATE” position. After all the air is expelled from 

the bed, return switch to the off position “O”.

3.  Roll or fold the AC cord and wand cord and secure it. Fold the sides of the bed into the 

center along its length. Tightly roll and place the bed in the convenient carry bag or other 

storage solution and store in a dry, clean location.

4.  Store your bed in a clean, dry place at room temperature (above 50 °F/10 °C). Storing your 

bed under 50 °F (10 °C) and over 100 °F (38 °C) may affect its performance and will not 

be covered under warranty.

SErVICINg OF DOUBLE-INSULATED PrODUCTS

In a double-insulated product, two systems of insulation are provided instead of grounding. 

No grounding means is provided on a double-insulated product, nor is a means for grounding 

to be added to the product. Servicing a double-insulated product requires extreme care and 

knowledge of the system, and is to be done only by qualified service personnel. Replacement 

parts for a double-insulated product must be identical to the parts they replace.

INSTRUCTION MANUAL

R111USB

Thank you for joining the AeroBed

®

 family by purchasing one of our products. You can expect top-notch quality, innovation and imagination from every AeroBed

®

 product. You are about to enjoy 

the comfort of an AeroBed

®

 product. It is your responsibility to read and always follow the safety, care and maintenance instructions for your new AeroBed

®

 product. Always instruct and supervise 

others on your bed’s proper use, maintenance and safety.

IMPOrTANT SAFETY

INFOrMATION AND WArNINgS

SAVE ThESE INSTrUCTIONS

rEAD AND FOLLOW ALL INSTrUCTIONS 

BEFOrE USINg ThIS PrODUCT.

Preparation of your AeroBed

®

 product requires no tools. Use of tools may damage your bed.

When using an electrical furnishing, basic precautions should always be followed, including 

the following: Read all instructions before using (this furnishing).

IMPORTANT

•  Product is for indoor use only. Do not use outdoors. For Household/Residential Use Only.
•  This product has not been evaluated for flammability or cigarette ignition resistance.

 WARNING

•  Use on flat surfaces only. Bed may tip over on uneven surfaces.
•  Remove all sharp objects from area where bed will be set up and used. Do not use this 

bed on abrasive surfaces or near pointed/sharp items or surfaces. Bed may puncture.

•  Unplug product when not in use.
•  Pump is not intended for continuous use. Pump may stop working or overheat if it is 

used for extended periods of time.

•  Do not use pump continuously for more than 10 minutes.
•  To avoid excessive heat build-up in pump, allow pump to cool off for 30 minutes after 

each 10 minutes of continuous use.

•  Do not attempt to disassemble, repair, or service the pump. No serviceable parts are 

contained inside. Contact The Coleman Company, Inc. at 3600 North Hydraulic, Wichita, 

KS 67219, 1-800-835-3278 or TDD 1-316-832-8707 in the United States or Sunbeam 

Corporation (Canada) Limited, DBA Jarden Consumer Solutions at 20B Hereford Street, 

Brampton ON  L6Y 0M1, 1-800-387-6161 in Canada for repair and service 

center information.

 WARNING

This is an electrical product - not a toy. To avoid risk of fire, burns, injury, or shock: 

•  Always unplug this furnishing from the electrical outlet before cleaning or servicing.
•  Use this product only for its intended use as described in these instructions. Do not use 

attachments not recommended by the manufacturer.

•  Never operate this product if it has a damaged cord or plug, if it is not working 

properly, if it has been dropped or damaged, or dropped into water.

•  Keep the cord away from heated surfaces.
•  Never operate the product with the air openings blocked. Keep the air openings free of 

lint, hair, and the like.

•  Never drop or insert any object into any opening.
•  Do not operate where aerosol (spray) products are being used or where oxygen is 

being administered.

•  Do not run cord under carpeting. Do not cover with throw rugs, runners or similar 

coverings. Arrange cord away from traffic area and where it will not be tripped over.

 WARNING

This is the closed position.

Open Air Release Valve.

Close Valve Using 2 Thumbs.

INFLATE

DEFLATE

ADJUST

Reviews: