CARE AND MAINTENANCE
CLEANING:
• Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.
• Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.
• Clean intake and exhaust vents by wiping with a dry, soft cloth.
Unlock access panel: to unlock, insert
the key provided and rotate counter-
clockwise ¼ turn.
Touch and hold the illuminated
indicator for three seconds
until a beep is heard and the
indicator is flashing green.
Open front access panel by pressing
latches on both sides of unit. Allow
panel to open fully. Remove filter(s)
to be replaced.
Release finger from indicator.
Remove any packaging wrap from the
new filters(s) and re-install the filters.
Touch and hold the indicator for
three seconds until a beep is heard
and the indicator light turns off.
1
FILTER REPLACEMENT INDICATORS:
The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon with Pre-Filter. The replacement period will vary depending on the hours of use, air
quality, and rate of air flow. However, under normal usage, most HEPA Filters need to be replaced every 2 years, and Carbon with Pre-Filter every 6 months. When a filter needs to
be replaced the following color will be shown on any one of the HEPA, CARBON, or ACCESSORY filter replacement indicators:
Red Flashing = RIGHT filter 90% full
Amber Flashing = LEFT filter 90% full
Red Flash, Pause, Amber Flash, Pause = Right & LEFT filters 90% full
Red = Replace RIGHT filter
Amber = Replace LEFT filter
Red & Amber Alternating = Replace Right & Left filters
Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax® PRO brand replacement filters as units will not function using any other
replacements.
FILTER REPLACEMENT PROCEDURE:
FILTER REPLACEMENT:
When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators. To reset the flashing filter
replacement indicator use the following procedure:
TROUBLESHOOTING
PROBLEM:
POSSIBLE SOLUTION:
The air quality control system fails to start.
• Check to assure unit is connected to power supply.
• Make sure filters are genuine AeraMax
®
PRO filters, as unit will not function with other
brands. IMPORTANT: Make sure filter detection area on genuine AeraMax
®
PRO
replacement filter aligns with window in filter frame.
• Review “Re-Installing Filters” section for further detail.
• Make sure front access panel is closed completely.
• Make sure power switch is on.
The unit makes a faint ticking sound.
•
This indicates that the “PlasmaTRUE™” bipolar ionizer is working.
The HEPA and/or Carbon Filter replacement indicator light
remain lit after replacing the filter(s).
• Repeat filter light reset instruction.
Note: If you do not complete step three within 10 seconds of completing step 1 then the indicator light will not be reset.
2
3
1
2
3