background image

5

AEROSMITH CONCRETE GAS TOOL OPERATIONAL MANUAL

AEROSMITH CONCRETE GAS TOOL OPERATIONAL MANUAL

AEROSMITH CONCRETE GAS TOOL OPERATIONAL MANUAL

2 - TROUBLESHOOTING

WARNING:

To reduce the risk of serious 

personal  injury,  ALWAYS 

unload the battery, the pins 

and fuel cell from the tool 

before all repairs.

A. Battery/Charger Problems

SYMPTOM 1

Battery Cell does not appear to accept charge. 

Green charger light does not come on after sev-

eral hours.

Possible 

reasons

Services

Inoperative 

indicator lights on 

charger.

Try Battery in tool after 

3 hours on charge cycle. 

If tool functions properly 

charger lights are not work-

ing correctly. Replace 

charger, or monitor time 

to ensure Battery Cell has 

adequate time for recharg-

ing. It’s normal for Battery 

to feel warm after properly 

charging.

Damaged 

charger.

Discontinue use imme-

diately and unplug from 

power source. Replace 

charger and tag or dispose 

of charger to prevent acci-

dental reuse or connection 

to power source.

SYMPTOM 2

Red LED on charger is blinking.

Possible 

reasons

Services

Battery is hot.

Remove battery from 

charger and allow to cool. 

Inspect battery charger 

and cartridge.

SYMPTOM 3

Orange LED on charger is blinking.

Possible 

reasons

Services

Charger 

damaged.

Replace Charger.

B. Normal Stage of Operation

SYMPTOM 1

Fan does not run.

Possible 

reasons

Services

Battery is not 

charged.

Charge Battery 

according to 

Operating Manual.

Battery 

Terminals or 

Handle 

battery contacts 

are oily, dirty, or 

corroded.

Clean Battery Cell termi-

nals Clean Handle Battery 

Cell contacts as required.

There is electrical 

short some-

where.

The tool must be looked 

into by Authorized Service-

man.

SYMPTOM 2

Fan does not run, or runs slower than normal.

Possible 

reasons

Services

Battery is dis-

charged.

Charge Battery Cartridge.

SYMPTOM 3

Fan runs intermittently.

Possible 

reasons

Services

Battery is loose 

or contacts are 

bent.

Snap battery back into its 

locked position. Bend 

contacts back into proper 

position.

C. Pre-Combustion/Combustion Stage 

of Operation

SYMPTOM 1

Contact Arm does not depress fully, tool does not 

Summary of Contents for GT38LI

Page 1: ...OPERATIONAL MANUAL GT38LI CONCRETE GAS TOOL...

Page 2: ...Plug the battery charger into the proper AC voltage source green light will be flashing 2 Insert the battery into charger red light will alight indicating the battery is charging 3 It takes about 60...

Page 3: ...at the bottom 2 Load the pins into the slit in the rear of the magazine until they reach the top of pin stopper 3 Further pull the follower holder press the button on the pin carrier and release it ge...

Page 4: ...in guide by bare hand or by any parts of the body Never point the tools at anybody Only pull the pin guide to separate the pin lock Steps 1 Remove the pins fuel cell and battery attached on the tool 2...

Page 5: ...tal reuse or connection to power source SYMPTOM 2 Red LED on charger is blinking Possible reasons Services Battery is hot Remove battery from charger and allow to cool Inspect battery charger and cart...

Page 6: ...Contact authorized ser viceman for repair Some dirt on the valve washer inside cylinder Contact authorized ser viceman for repair Valve wave washers lose elasticity Contact authorized ser viceman for...

Page 7: ...are dirty Contact authorized ser viceman for repair SYMPTOM 4 Unstable performance Possible reasons Services Built up dirt and debris inside cylinder Contact authorized ser viceman for repair SYMPTOM...

Page 8: ...y is assumed for direct or consequential damages resulting from the improper use of the tool The national safety and occupational safety regulations and the safety precautions given in this operating...

Reviews: