DA20-100 ‘Katana’ 4X Manual
Neither the software nor the documentation may
be used for real aviation and training purposes.
03<08
page
3.3.3 FIRE
a) Engine Fire during Engine-Start-Up on the Ground
1.
Fuel Shut-off Valve
2.
Throttle
FULL
CLOSED
3.
5.
Master Switch (Battery)
Evacuate Airplane immediately
OFF
4.
Ignition Switch
OFF
EMERGENCY PROCEDURES
CAUTION:
!
If fire extinguisher is used, the cabin must be aerated.
b) Engine Fire during Flight
1.
Fuel Shut-off Valve
2.
Airspeed (V
IAS
)
70 kts / 81 mph / 130 km/h
CLOSED
3.
5.
7.
Flaps
Electric Fuel Pump
Perform emergency landing with engine
off according to paragraph 3.3.2
T/O
4.
6.
Throttle
Cabin Heat
FULL
OFF
CLOSED
c) Electrical Fire including Smoke during Flight
1.
Master Switch (Battery)
2.
Cabin Air
OPEN
OFF
3.
Fire Extinguisher
use only if smoke development
continues.