NOTE:
!
There are 30 minutes of battery life remaining at a discharge load of
20 amperes.
DA20-100 ‘Katana’ 4X Manual
EMERGENCY PROCEDURES
Neither the software nor the documentation may
be used for real aviation and training purposes.
03<13
page
c) Low Voltage Indication (needle in yellow Arc)
1.
I. LOW VOLTAGE INDICATION (NEEDLE IN YELLOW ARC) WHILE
AIRPLANE ON GROUND
1.
3.
Propeller RPM
If needle remains in the yellow
arc and the ammeter is indicating
to the left of centre (discharge)
Increase RPM until needle is
in the Green Arc. This should
occur before exceeding
1350 RPM.
Discontinue any planned flight
activity
2.
Non-flight essential electrical
consumers
Switch OFF consumers until
needle is in the Green Arc.
1.
II. LOW VOLTAGE INDICATION (NEEDLE IN YELLOW ARC) DURING
FLIGHT
1.
All non-flight essential electrical
consumers
Switch OFF
2.
Generator Failure: Refer to
paragraph 3.3.9 (b)
If needle remains in the yellow
arc and the ammeter is indicating
to the left of centre (discharge)