NORMAL OPERATION
4.3.
STRUCTURAL TEMPERATURE INDICATOR
A structural temperature indicator, installed on the spar bridge, indicates
when the structural temperature limitation is exceeded. The indicator
need only be checked if the OAT exceeds 38° C (100° F).
The indicator is accessed by lifting the flap between the two seatback
cushions. The indicator is visible through the cut out in the seat shell
backs.
At temperatures below the 55° C (131° F) limit, the indicator appears all
red with a faint indication of “55” (° C). At temperatures exceeding the 55°
C (131° F) limit, the indicator displays a clearly contrasting red “55” (° C)
on a black background.
NOTE:
FSX OPERATION:
!
!
At temperatures approaching the limit, the background will
progressively darken prior to turning black; this indicates acceptable
temperatures.
The temperature sensor is accessed by clicking on the lower area
between the two seatback cushions.
55
55
Red “55” on black background
indicates that structural
temperature limit is exceeded.
Flight is prohibited.
All red indicates that structural
temperature is below limit. Flight
is permitted.