CHT-100 Cylinder Head Temperature Indicator
Page 4 of 11
Aerospace Logic Inc.
3150 Ridgeway Drive, Unit #43, Mississauga, Ontario, L5L 5R5, CANADA
Tel. (905) 569-3887 | Fax. (416) 352-5854 | Email. sales@aerospacelogic.com
www.aerospacelogic.com
CHT-100 Operations & Installation Manual – Ver. 1.9 – June 5, 2003
Thermocouple signal cables are red/white twisted pairs. The colors listed refer to
the tag color on the wire pair. Green and yellow tags are only on 6 cylinder
instruments.
BLACK
Cylinder 1
BLUE
Cylinder 4
RED
Cylinder
2
GREEN
Cylinder
5
WHITE
Cylinder
3
YELLOW
Cylinder
6
If you have purchased a complete instrument and probe kit appropriate
connectors for interconnection of the signal wires and probe leads are provided.
If you have purchased only the instrument NO connectors are provided as there
is no way of determining what type of probes will be used. In this case the
installer is to provide the necessary connectors.
For installation of the complete kit, simply snap the connectors together for the
appropriate cylinders, slide the included heat shrink sleeves over the connection
and shrink to size. Take care in matching the correct color coded signal pair to
the correct cylinder.