EGT-100 Operations & Installation Manual – Ver. 1.9 – June 5, 2003 

 

6. Probe 

Installation

 

 

NOTE:

 This section refers primarily to installation of probes supplied as a kit 

with the specific instrument. For installation using existing or owner supplied 
probes please see the specific probe manufacturer information. 
 
The instrument will support all grounded and ungrounded probes that meet 
the requirements listed in the Specification Section. 
 

Thermocouple / Signal Wire Junction

 

 
Where possible, plan the installation such that the junction between the 
thermocouple and signal wire takes place on the cockpit side of the firewall. If 
this is not possible ensure that the junction is in the coolest possible location 
in the engine compartment. 
 
Ensure that ALL thermocouple leads are strapped together at the junction 
point. This will further eliminate the possibility of any ground loop problems. 
 

Connection

 

 
Thermocouple leads are marked with red (negative) and yellow (positive) 
sleeves and match the corresponding red and yellow twisted pair signal 
wires. Simply snap the corresponding connections together, slide the heat 
shrink sleeve over the junction and shrink to size when installing the 
instrument. 
 
For installation of the probe end into the exhaust please see the illustration as 
below: 
 

 

 
 
 
 

Summary of Contents for EGT-100 Series

Page 1: ...0 Exhaust Gas Temperature Indicator This instrument is a complex precision instrument manufactured to exceed Airborne Equipment Standards DO 160D DO 178B and TSO C43c standards In order for your instr...

Page 2: ...ensure that it is functioning correctly In turn the main processor validates the independent monitoring processor Any failure detected in either processor and your instrument display will be shut down...

Page 3: ...ure proper operation The instrument has been software calibrated and never needs recalibration provided no wiring modifications are made at installation time Now connect the supply and dimmer wiring T...

Page 4: ...e purchased a complete instrument and probe kit appropriate connectors for interconnection of the signal wires and probe leads are provided If you have purchased only the instrument NO connectors are...

Page 5: ...Page 5 of 11 Aerospace Logic Inc 3150 Ridgeway Drive Unit 43 Mississauga Ontario L5L 5R5 CANADA Tel 905 569 3887 Fax 416 352 5854 Email sales aerospacelogic com www aerospacelogic com EGT 100 Operatio...

Page 6: ...the setup mode the display bar will remain blank The CYL digit and the four digit display shows the parameter value and type as per the enclosed instructions In order to set the manufacturer specified...

Page 7: ...ch once to the S position and release The low limit will now be saved and applied to all cylinders The display will move to the next parameter H High Temperature Limit Set The high temperature limit s...

Page 8: ...splay the STEP message for approximately five seconds before starting the step process Once started it will step through all cylinders When the last is reached it will revert back to the first 1 Displ...

Page 9: ...nt and should be used during leaning and normal operations Leaning in the automatic mode ensures that no cylinder is overheated during the process If the instrument is switched from the automatic mode...

Page 10: ...Section Thermocouple Signal Wire Junction Where possible plan the installation such that the junction between the thermocouple and signal wire takes place on the cockpit side of the firewall If this i...

Page 11: ...for thermocouple sensor linearity Minimum 256 times measurement validation before display Operating Temperature 15 C to 55 C 5 F to 131 F Power Consumption 370mA Max daytime operation 50mA Min nightt...

Reviews: