20
G
B
POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
5
FAULT
CAUSE
REMEDY
Reduction of performance. Frequent start-up.
Low pressure values.
Excessive performance request, check for any
leaks from the couplings and/or pipes. Intake
filter may be clogged.
Replace the seals of the fitting, clean or replace
the filter.
The compressor stops and restarts
automatically after a few minutes.
Tripping of the thermal cutout due to
overheating of the motor.
Clean the air ducts in the conveyor. Ventilate
the work area.
After a few attempts to restart, the compressor.
Tripping of the thermal cutout due to
overheating of the motor (removal of the
plug with the compressor running, low power
voltage).
Activate the on/off switch. Ventilate the work
area. Wait a few minutes. The compressor will
restart independently. Remove any power cable
extensions.
The compressor does not stop and the safety
valve is tripped.
Irregular functioning of the compressor or
breakage of the pressure switch.
Remove the plug and contact the Service
Center.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts. Tampering with the machine may impair
its safety and in any case make the warranty null and void.
Warranty and repair.
In the event of defective goods or requirements for spare parts, kindly contact the sales point where you made your purchase.
CLEANING AND MAINTENANCE
4
Warning!
Pull the power plug before doing any cleaning and maintenance work
on the appliance.
Warning!
Wait until the compressor has completely cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying out any cleaning and
maintenance work.
Never clean the machine and its components with solvents, flammable or
toxic liquids. Us only a damp cloth making sure you have unplugged the
compressor from the current outlet.
After approx. 2 hours of use, the condensate that has formed must be
drained from the receiver. First of all, vent all the air using the accessory
connected, as described above.
The condensation water must be drained off each day by opening the drain
valve (ref. 11) (on the bottom of the pressure vessel).
Warning!
If the water that condenses is not drained, it may corrode the receiver,
reducing its capacity and impairing safety.
As it is a contaminating product, condensate must be DISPOSED of
in accordance with laws on protection of the environment and current
legislation.
The compressor must be disposed in conformity with the methods
provided for by local regulations.
Summary of Contents for BRICO
Page 9: ...9 1a 1b 2 1 1 11 4 11 10 5 7 BRICO OL 195 6 6 4 6 3 9 7 5 2 9...
Page 10: ...10 1c 1d 2 1 1 11 3 OL 195 24 OL 195 50 4 8 8 3 9 5 7 6 12 2 9 5 7 6 12 4 11...
Page 11: ...11 1e 9 8 2 5 FIFTY 6 4 3 11 1 7 1f CENTURY 5 6 12 2 7 10 8 4 3 11 9 1...
Page 12: ...12 1h 1 4 11 10 7 OM 200 6 SIL 12 2 9 8 6 1g OM 231 10 SIL 11 2 1 9 3 4 12 8 7 6 5 10...
Page 16: ...16 7e 15 17 4 16 CENTURY...
Page 38: ...38 G R 2 bar I O 10 7 6 5 4 2 11 5...
Page 52: ...52 R U O 2 10 7 6 5 4 11 5...
Page 60: ...60 B G 2 I O 10 7 6 5 4 11 5...
Page 69: ...63 230V Ac 50 Hz 120V Ac 60 Hz 230V Ac 50 Hz 120V Ac 60 Hz 69...
Page 70: ...63 230V Ac 50 Hz 120V Ac 60 Hz 230V Ac 50 Hz 120V Ac 60 Hz 70...
Page 71: ...63 230V Ac 50 Hz 120V Ac 60 Hz 230V Ac 50 Hz 120V Ac 60 Hz 71...