4/28/2021
Nano Shutter User Guide : Aeotec Help Desk
https://aeotec.freshdesk.com/support/solutions/articles/6000198854-nano-shutter-user-guide-
12/15
3. Calibration termination
If the motor movement direction is found to be incorrect during calibration (see Venetian calibration mode), the
calibration can be terminated by short pressing 3 times / 5 times or sending the Configuration Set command (see
Parameter 34 and 35).
4. Repositioning
Nano Shutter may experience positional deviation after a long-term operation or external force. Errors can be
eliminated
by repositioning.
a)
Send a Configuration Set [Parameter 40 to value 1] command to enter repositioning;
b)
The percentage position at which the product motor starts is recorded and motor moves to reference point A for a
duration of Shutter Trip Time + Venetian Turn Time;
c)
The motor reverses and returns to the starting percentage position and the repositioning is complete.
Advanced functions.
Removing Nano Shutter from a Z-Wave network.
Your Nano Shutter can be removed from your Z-Wave network at any time. You’ll need to use your Z-Wave network’s main
controller. To set your Z-Wave controller/gateway into removal mode, please refer to the respective section within your
controller instruction manual.
1.
Set your Z-Wave controller into removal mode.
2.
Press the Action Button on the Nano Shutter 6x times within 2 seconds.
3.
if the Nano Shutter has been successfully removed from your Z-Wave network, its RGB LED will remain colorful
gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load), repeat
the instructions above from step 1.
Changing mode on the External Switch/Button Control.
The Nano Shutter can be controlled via 2-state (flip/flop) external/manual switch, momentary push button or the 3-way
switch. To automatically detect and set the mode to the appropriate type of manual switch wired into Nano Shutter, toggle
the button on the manual switch once and wait 2 seconds for the Nano Shutter to detect the type of manual switch.
You can also set the external switch mode through Configuration Command Class.
Parameter 120 [1 byte] (for S1) and Parameter 121 [1 byte] (for S2) is the parameter that will set one of the 3 different
modes. You can set this configuration to:
(0)
Unknown Mode
(1)
2-state switch mode
(2)
3-way switch mode
(3)
Momentary push button Mode
(4)
Enter auto switch detection mode