Only a licensed electrician with knowledge and understanding of electrical systems and safety should complete the
installation.
The maximum amperage rating for Nano Shutter is 2.5A for each slot and 5A for both when connecting a motor load:
(COSφ=0.4, L/R=7ms)
Keep product away from open flames and extreme heat. Avoid direct sunlight or heat exposure.
Nano Shutter is intended for indoor use in dry locations only. Do not use in damp, moist, and/or wet locations.
Install the Nano Shutter.
Nano Shutter installs behind a switch or a momentary push button. It works with only 3-wire (with neutral) lighting setups,
though each installation of Nano Shutter is accordingly slightly different:
1. Shut off the main circuit breaker of your home for safety during the installation and ensure the wires are not short-
circuited during the installation which will cause damage to the Nano Shutter.
Note:
Your home’s main circuit breaker must support the overload protection for safety.
2. Preparing connection wires
14 AWG power wires for Input / Output.
18 AWG copper wires for the external manual switch.
Use the wire stripper cut the metallic part of the connection wire and make sure the length of the metallic part is about
5mm.
Note:
All connection wires needs to be a flexible cable for the easiest installation.
120-230VAC Wiring diagram of Nano Shutter.