background image

1.4. AC Power Setting

You can change the BIOS setting on the PC so that, in the event of a power failure, you will not need to
access the PC to manually turn the PC back on. Use this item to select AC power state when power is re-
applied after a power failure.

Table 1-4:

BIOS Settings

PC Type

BIOS Category

Settings

-CC04
-CC05

State after G3

Power On

-R103

Restore AC Power Loss

S0 State

-R402

Restore AC Power Loss

S0 State

-DT01

Restore AC Power Loss

S0 State

1.5. DVI Monitor Configuration (-R103, -R402, -DT01 PC Options)

To let the Windows OS operate without a monitor connected, both the AIMB-785 motherboard and the
standard Advantech-provided BIOS are configured to report to the Windows OS that a VGA monitor is
always connected as the default primary display. If you connect a single DVI monitor to one of the rack
mount (-R103 or -R402) or desktop (-DT01) computers, the BIOS will continue to report to Windows that
the VGA monitor is also connected. You will need to update the Windows Display settings to get the
system to correctly identify the DVI monitor. Either duplicate the Windows desktop to both monitors or
identify and set the DVI monitor as the primary display.

1.6. Environmental Specifications

Table 1-5:

Environmental Specifications

Ambient
Temperature

Operating: 0° to 40°C
Storage: -30° to 85°C

Humidity
Non-condensing

The maximum relative humidity is 80% for temperatures that are less
than 31°C and decreases linearly to 50% relative humidity at 40°C.

Operating Altitude

0 m to 2,000 m above sea level.
If you must operate this product above 2,000 m or below sea level,
contact Aerotech, Inc.

Pollution

Pollution Degree 2
Typically only nonconductive pollution occurs.

Operation

Use only indoors

1.4. AC Power Setting

Automation1 iPC Hardware Manual

18

www.aerotech.com

Summary of Contents for Automation1 iPC Series

Page 1: ...Revision 1 00 Automation1 iPC Intelligent Industrial PC HARDWARE MANUAL ...

Page 2: ...ut repairs and spare or replacement parts To get help immediately contact a service office or your sales representative Include your customer order number in your email or have it available before you call This manual contains proprietary information and may not be reproduced disclosed or used in whole or in part without the express written permission of Aerotech Inc Product names mentioned herein...

Page 3: ... Chapter 1 Automation1 iPC 9 1 1 Specifications 10 1 2 Remote Server Operation 12 1 3 Dimensions 14 1 4 AC Power Setting 18 1 5 DVI Monitor Configuration R103 R402 DT01 PC Options 18 1 6 Environmental Specifications 18 Appendix A Warranty and Field Service 19 Appendix B Revision History 21 Index 23 www aerotech com 3 Automation1 iPC Hardware Manual Table of Contents ...

Page 4: ...inet Dimensions CC04 CC05 15 Figure 1 7 4U Rack Mount Chassis Dimensions R402 16 Figure 1 8 1U Rack Mount Chassis Dimensions R103 17 List of Tables Table 1 1 Ordering Options 9 Table 1 2 Automation Motion Server Specifications Control Cabinet Desktop PC 10 Table 1 3 Automation Motion Server Specifications Rack Mount PCs 11 Table 1 4 BIOS Settings 18 Table 1 5 Environmental Specifications 18 List o...

Page 5: ...tructions CC04 CC05 Control Cabinet PCs EN 55011 2009 A1 2010 Group 1 Class A EN 55032 2015 AC 2016 Class A CISPR 32 2015 COR1 2016 Class A EN 61000 6 4 2007 A1 2011 EN 61000 3 2 2014 Class D EN 61000 3 3 2013 EN 55024 2010 A1 2015 EN 61000 6 2 2005 AC 2005 EN 61000 4 2 2009 EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2012 EN 61000 4 5 2014 EN 61000 4 6 2014 AC 2015 EN 61000 4 8 2010 EN 61000 4...

Page 6: ...2 2009 EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2012 EN 61000 4 5 2014 EN 61000 4 6 2014 AC 2015 EN 61000 4 8 2010 EN 61000 4 11 2004 Authorized Representative Simon Smith European Director Address Aerotech Ltd The Old Brick Kiln Ramsdell Tadley Hampshire RG26 5PR UK Name Alex Weibel Position Engineer Verifying Compliance Location Pittsburgh PA Date 7 24 2020 EU Declaration of Conformity Aut...

Page 7: ...05 Desktop PC DT01 1U Rack Mounted PC R013 4U Rack Mounted PC R402 This is to certify that the aforementioned product s is in accordance with the applicable requirements of the following Standard s FCC Part 15 Subpart B ANSI C63 4 2014 ICES 003 Issue 6 2016 CISPR 22 2008 CAN CSA CISPR 22 10 www aerotech com 7 Automation1 iPC Hardware Manual Agency Approvals ...

Page 8: ...This page intentionally left blank Agency Approvals Automation1 iPC Hardware Manual 8 www aerotech com ...

Page 9: ...Windows 10 LTSC 64 bit operating system default Motion Bus Hardware MB03 HyperWire motion bus through a PCIe interface card MB00 No motion bus interface card Automation Bus Hardware AB04 EtherCAT interface card HyperWire PCIe add on AB03 3 EtherCAT interface card and Ethernet expansion card AB01 3 Ethernet expansion card AB00 No EtherCAT PROFINET interface card or Ethernet expansion cards default ...

Page 10: ... Power 24 VDC 24 VDC 100 240 V 2 4 A 50 60 Hz Display Connections Display Port HDMI Display Port HDMI VGA DVI D 2 Available PCI PCIe Expansion Slots 3 N A N A 1 x PCIe x16 2 x PCIe x4 3x PCI DVD Drive No No Yes Drive Interface HyperWire HyperWire HyperWire LAN 10 100 1000 Mbit Qty 2 10 100 1000 Mbit Qty 2 10 100 1000 Mbit Qty 2 Modbus Support Yes Ethernet Yes Ethernet Yes Ethernet EtherCAT PROFINE...

Page 11: ...ilable PCI PCIe Expansion Slots 3 N A 1 x PCIe x16 2 x PCIe x4 3 x PCI DVD Drive Yes Yes Drive Interface HyperWire HyperWire LAN 10 100 1000 Mbit Qty 2 10 100 1000 Mbit Qty 2 Modbus Support N A Yes Ethernet EtherCAT PROFINET Support N A Available Power Supply 350 W 400 W 1 To avoid machine disruption Aerotech disables automatic updates on Windows PCs that are shipped from Aerotech To customize you...

Page 12: ...ith the remote server Refer to the figures below to determine which port you should use for each Automation1 iPC hardware configuration Figure 1 1 CC04 CC05 Connector View typical Figure 1 2 DT01 Connector View typical 1 2 Remote Server Operation Automation1 iPC Hardware Manual 12 www aerotech com ...

Page 13: ...Figure 1 3 R103 Connector View typical Figure 1 4 R402 Connector View typical www aerotech com 13 Automation1 iPC Hardware Manual 1 2 Remote Server Operation ...

Page 14: ...rseded at any time All drawings and illustrations are for reference only and were complete and accurate as of this manual s release Refer to www aerotech com for the most up to date information Figure 1 5 Desktop Computer Dimensions DT01 1 3 Dimensions Automation1 iPC Hardware Manual 14 www aerotech com ...

Page 15: ...Figure 1 6 Control Cabinet Dimensions CC04 CC05 www aerotech com 15 Automation1 iPC Hardware Manual 1 3 Dimensions ...

Page 16: ...Figure 1 7 4U Rack Mount Chassis Dimensions R402 1 3 Dimensions Automation1 iPC Hardware Manual 16 www aerotech com ...

Page 17: ...Figure 1 8 1U Rack Mount Chassis Dimensions R103 www aerotech com 17 Automation1 iPC Hardware Manual 1 3 Dimensions ...

Page 18: ...VI monitor to one of the rack mount R103 or R402 or desktop DT01 computers the BIOS will continue to report to Windows that the VGA monitor is also connected You will need to update the Windows Display settings to get the system to correctly identify the DVI monitor Either duplicate the Windows desktop to both monitors or identify and set the DVI monitor as the primary display 1 6 Environmental Sp...

Page 19: ...ber must accompany any returned product s The RMA number may be obtained by calling an Aerotech service center or by submitting the appropriate request available on our website www aerotech com Products must be returned prepaid to an Aerotech service center no C O D or Collect Freight accepted The status of any product returned later than thirty 30 days after the issuance of a return authorization...

Page 20: ...ditions stated in the following On Site Non Warranty Repair section apply On site Non Warranty Repair If any Aerotech product cannot be made functional by telephone assistance or purchased replacement parts and cannot be returned to the Aerotech service center for repair then the following field service policy applies Aerotech will provide an on site Field Service Representative in a reasonable am...

Page 21: ...Appendix B Revision History Revision Description 1 00 New Manual www aerotech com 21 Automation1 iPC Hardware Manual Appendix B Revision History ...

Page 22: ...This page intentionally left blank Appendix B Revision History Automation1 iPC Hardware Manual 22 www aerotech com ...

Page 23: ...perature 18 D Declaration of Conformity 5 E Electromagnetic Compatibility EMC 5 EU 2015 863 5 H Humidity 18 O Operation 18 P Pollution 18 R Revision History 21 T Table of Contents 3 U Use 18 W Warranty and Field Service 19 www aerotech com 23 Automation1 iPC Hardware Manual Index ...

Page 24: ...Index Automation1 iPC Hardware Manual 24 www aerotech com This page intentionally left blank ...

Reviews: