DR500 Operation and Technical Manual
Set Up
Version 1.6
Aerotech, Inc.
2-3
2.2.1. Rear Panel Interface Board Internal Jumpers
This section covers the configurations of the slot jumpers on the DR500 Rear Panel
Interface board. Table 2-1 lists the configurations and jumper selections for the Rear
Panel Interface board.
Table 2-1.
Rear Panel Interface Board Jumper Selections
Configuration
Jumpers
Standard
Optional
Power to Opto Coupled D/A’s
(U500PCI Only)
Remove JP1, JP2, JP3, JP4
Insert JP1, JP2, JP3, JP4
(U500 PCI Only!)
Auxiliary Encoder Fault Input
None
Disables Amp
Drives Mode
Input
Axis 1
Remove JP5
JP5 1-2
JP5 2-3
Axis 2
Remove JP6
JP6 1-2
JP6 2-3
Axis 3
Remove JP7
JP7 1-2
JP7 2-3
Axis 4
Remove JP8
JP8 1-2
JP8 2-3
Brake Output to Axis Connector
No Brake
Brake Present
Axis 1 – J2
Remove JP28A, JP29A
JP28A 1-2, JP29A 1-2
Axis 2 – J3
Remove JP28B, JP29B
JP28B 3-4, JP29B 3-4
Axis 3 – J4
Remove JP28C, JP29C
JP28C 5-6, JP29C 5-6
Axis 4 – J5
Remove JP28D, JP29D
JP28D 7-8, JP29D 7-8
5 Volt Operation
24 Volt Operation
E-Stop Voltage Level
Insert JP14
Remove JP14
Isolate Pins 20 to 17 of J11 I/O Bus
Insert JP9, 10, 11, 12 (U500)
Remove JP9, 10, 11, 12 (U600)
JP13 is always out
2.2.2. Drive Interface Board Internal Jumpers
This section covers the configurations of the slot jumpers on the DR500 Drive Interface
Board. Figure 2-2 displays the Drive Interface Board internal jumper locations and
Table 2-2 lists the configurations and jumper selections.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com