DR500 Operation and Technical Manual
Set Up
Version 1.6
Aerotech, Inc.
2-17
Figure 2-7.
Transfer Function of Pre-Amplifier Circuit
Input Pot Full CCW
Input Pot Full CW
Gain Pot Center
Gain Pot Full CW
80
60
40
20
0
.1
1
10
100
1000
10000
100000
Gain
(dB)
Transfer
Function
Icom
Vcom
Frequency (Hz)
Tach Pot Full CCW
Tach Pot Full CW
Gain Pot Center
Gain Pot Full CW
80
60
40
20
0
.1
1
10
100
1000
10000
100000
Gain
(dB)
Transfer
Function
Icom
Vfb
Frequency (Hz)
Note:
Transfer functions shown above are with respect to values of
RCN4 shown in Figure 2-5.