Technical Details
DR500 Operation and Technical Manual
3-6
Aerotech, Inc.
Version
1.6
Each of the following end of travel limit switch inputs (39-50) are contact closure signals.
See the UNIDEX 500/U600 manuals for additional information concerning the end of
travel limits.
Pin 39 - CW Limit Axis 1
When activated, this signal immediately stops all
clockwise motion of the motor.
Pin 40 - CCW Limit Axis 1
When activated, this signal immediately stops all counter
clockwise motion of the motor.
Pin 41 - CW Limit Axis 2
When activated, this signal immediately stops all
clockwise motion of the motor.
Pin 42 - CCW Limit Axis 2
When activated, this signal immediately stops all counter
clockwise motion of the motor.
Pin 43 - CW Limit Axis 3
When activated, this signal immediately stops all
clockwise motion of the motor.
Pin 44 - CCW Limit Axis 3
When activated, this signal immediately stops all counter
clockwise motion of the motor.
Pin 45 - CW Limit Axis 4
When activated, this signal immediately stops all
clockwise motion of the motor.
Pin 46 - CCW Limit Axis 4
When activated, this signal immediately stops all counter
clockwise motion of the motor.
Pin 47 - Home Limit Axis 1
This is the home limit switch output for axis 1. It is the
same as the CW/CCW limit outputs except that it is used
only during the home cycle to find a reference point to
begin looking for the once per revolution marker pulse.
Pin 48 - Home Limit Axis 2
Refer to the description given for pin 47.
Pin 49 - Home Limit Axis 3
Refer to the description given for pin 47.
Pin 50 - Home Limit Axis 4
Refer to the description given for pin 47.
Pins 53 - +12V
This pin may be an input or output. On U500 and U600
ISA controllers, this pin is driven from the +12V from
the ISA bus.
On U500 PCI, this pin may be an input (+12V) to power
the DAC’s. See the U500 manual for more information.
Pins 54 - +12V/Common
On U500/U600 ISA controllers, this pin is driven from
the +12V from the ISA bus.
On the U500 PCI, this pin may be the common for the
DAC’s when using an isolated power supply. See the
U500 manual for more information.
WARNING
WARNING
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com