Figure 4-1:
Ball Joint Location
4.3. Troubleshooting
Table 4-2:
Troubleshooting
Symptom
Possible Causes and Solutions
Strut will not move
A Cable is Disconnected
:
Check the cables for connections and damage.
Limit or Controller Fault
:
Check the controller for faults. Refer to the controller and software
documentation.
Strut moves
uncontrollably
Encoder Signal Connection
or the
Motor Signal Connection
:
Check to make sure that the cable connections are secure.
Refer to the
Section 3.2. Motor and Feedback Wiring
Axes are unstable or
squeal
Incorrect Gains
:
Refer to controller documentation
Hardware Manual
HEX500-350HL
www.aerotech.com
43