Electrical Specifications and Installation
LaserTurn
®
1 Hardware Manual
Table 3-9:
Linear Axis Motor Specifications (BLMUC-111-A)
BLMUC-111
Performance Specifications
(1) (5)
Continuous Force, 1.4
bar (20 psi)
(2)
N (lb)
46.9 (10.5)
Continuous Force, No
Forced Cooling
(2)
N (lb)
30.6 (6.9)
Electrical Specifications
(5)
Winding Designation
-A
BEMF Constant (line-
line, max)
V/(m/s) (V/(in/s))
11.35 (0.29)
Continuous Current
1.4 bar (20 psi)
(2)
A
pk
(A
rms
)
4.75 (3.36)
Continuous Current,
No Forced Cooling
(2)
A
pk
(A
rms
)
3.10 (2.19)
Peak Current, Stall
(3)
A
pk
(A
rms
)
19.00 (13.44)
Force Constant,
Sine Drive
(4) (8)
N/A
pk
(lb/A
pk
)
9.87(2.22)
N/A
rms
(lb/A
rms
)
13.96 (3.14)
Motor Constant
(2) (4)
N/√W (lb/√W)
3.78 (0.85)
Resistance, 25°C
(line-line)
Ω
6.5
Inductance (line-line)
mH
0.87
Thermal Resistance,
1.4 bar (20 psi)
°C/W
0.65
Thermal Resistance,
No Forced Cooling
°C/W
1.52
Maximum Bus Voltage
V
DC
340
1. Performance is dependent upon heat sink configuration, system cooling conditions, and ambient temperature
2. Values shown @ 100°C rise above a 25°C ambient temperature, with motor mounted to the specified aluminum heat sink.
3. Peak force assumes correct rms current; consult Aerotech.
4. Force constant and motor constant specified at stall
5. All performance and electrical specifications ±10%
6. Maximum winding temperature is 125°C.
7. Ambient operating temperature range 0 °C - 25 °C; consult Aerotech for performance in elevated ambient temperatures
8. All Aerotech amplifiers are rated Apk; use force constant in N·m/Apk when sizing.
34