2.5.7. Differential Analog Input 0 (J205)
To interface to a single-ended (non-differential) voltage source, connect the signal common of the source to
the negative input and the analog source signal to the positive input. A floating signal source should be
referenced to the analog common as shown in
.
Table 2-35:
Differential Analog Input 0 Specifications
Specification
Value
(AI+) - (AI-)
+10 V to -10 V
(1)
Resolution (bits)
16 bits
Resolution (volts)
305 µV
1. Signals outside of this range may damage the input
Table 2-36:
Analog Input Pins on the Auxiliary I/O Connector (J205)
Pin#
Description
In/Out/Bi
13
Analog Input 0 + (Differential)
Input
14
Analog Input 0- (Differential)
Input
23
Analog Common
-
Figure 2-33:
Analog Input 0 (J205)