Maintenance
Table 6-4:
Control Board Fuse Information
Fuse
Description
Size
Aerotech P/N
Manufacturer's P/N
F1
Radial Lead Resettable Fuse
3 A
EIF01001
Littelfuse RGEF300
F2
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F3
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F4
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F5
Surface Mount Fuse
.05 A
EIF01028
Raychem MICROSMD005F-2
F6
Resettable Fuse
.5 A
EIF01002
Littelfuse MINISMDC050F-2
Table 6-5:
LED Description
LED
Description
ENB/FLT
Turns green to indicate that the axis is enabled. Turns red to indicate a fault condition. The
ENB/FLT LED will flash between RED and GREEN if the drive is enabled and in a fault
condition.
MARKER
Turns green to indicate that the marker input is high.
PWR*
Turns green when power is applied.
POS
Turns green to indicate that the axis is in position.
* If the power light flashes continuously and the unit does not operate, there is too much current draw from the 5V power supply or
the control supply voltage level is low.