pag.
53 di 64
Use and Maintenance Manual
M
MCCHH88--1111//EEM
M -- M
MCCHH1133--1166//EETT
Standard
Cap.8 _ Storage
8 - STORAGE
Should the compressor not be used, it must be stored in a dry sheltered area at an ambient temperature of
between 0 °C and 40 °C.
Store the compressor away from sources of heat, flames or explosive.
STOPPING THE MACHINE FOR A BRIEF PERIOD
8.1
STOPPING THE MACHINE FOR A LONG PERIOD
8.2
If you do not intend to use the compressor for a brief period proceed with general cleaning.
If you do not intend to use the compressor for a long period, extract the active carbon filter cartridge.
Run the compressor for a few minutes without actually filling bottles so as to flush out all the residual
condensate. Stop the compressor, disassemble the intake filter, restart the compressor and spray a few drops
of oil into the air intake hole so that a light film of lubricant is aspirated and penetrates the interior of the
compressor. Stop the compressor and refit the air intake filter. Clean the external parts: eliminate any
moisture, salt or oil deposits. Protect the compressor from dust and water by storing it in a clean, dry place.
Switch off the machine via the main switch and remove the plug from the mains power socket.
Proceed with a thorough general clean of all machine parts.
During machine downtimes it is advisable to run the compressor for 20 minutes every 15 days.