Cap.4 _ Technical data
pag.
27
Use and maintenance manual
MCH-36
4.1.6 - TECHNICAL SPECIFICATIONS TABLE
4.1.7 - NOISE LEVEL
Construction
high pressure compressor with forced air
cooling and 4 compression stages
Max. peak non-continuous pressure
225bar - 3300PSI
330bar - 4700PSI
Flow rate
approx. 600 l/min. 21 cfm
Cylinder diameter
130 - 60 - 32 - 14 mm
Piston stroke
50 mm
RPM
1300 rpm
Intermediate pressures
1
st
stage 3.5 bar – 50 PSI
2
nd
stage 18 bar – 260 PSI
3
rd
stage 70 bar – 1000 PSI
4
th
stage 225 bar – 3300 PSI
5
th
stage 330 bar – 4700 PSI
Oil pressure
4 bar cold
1.5 bar during routine use
1 bar minimum pressure
Motor power
15kW
Voltage and frequency
400V - 50Hz
440V - 60Hz
230V - 50Hz
230V - 60Hz
WORK AREA
The MCH-36 compressors have been designed and
built to reduce noise pollution to a minimum.
Compressor noise levels were measured in the
“operator” (work) area.
Should the compressor be used where the daily noise exposure level is greater than 80 dBA,
the employer must apply all the relevant worker health and safety measures.
Where necessary operators must use personal protection such as ear defenders.
WARNING:
MCH-36 SILENT:
MCH-36 OPEN V.M.: