Cap.5 _ Handling and installation
pag.
30
Use and maintenance manual
MCH-36
5.2 - HANDLING
After separating the compressor from its packaging it can be transported to the designated placement area.
Transfer will require the use of a fork-lift truck or transpallet (of suitable load-bearing capacity): the forks must
be inserted in the feet of the europallet on which the compressor is positioned. The compressor has runners
for handling with fork-lift trucks or transpallets.
5.3 - INSTALLATION
- Position the compressor in the designated area and check it is level. For compressor dimensions please
consult section 4.1.8 “Dimensions and weights”.
- Check that the area in which the compressor is to be positioned is adequately ventilated: good air
exchange (more than one window), no dust and no risk of explosion, corrosion or fire.
- If ambient temperatures exceed 45°C air conditioning will be necessary.
- Position the compressor no closer than 1 m to surrounding walls; the gap between compressor and
ceiling should be at least 1.5 m. These distances ensure proper compressor operation and proper cooling
of the pumping unit.
- Make sure that lighting in the area is sufficient to identify every detail (such as the writing on the info
labels); use artificial lighting where daylight is on its own insufficient.
Before proceeding with the installation tasks described below, read Chapter 3 “SAFETY
REGULATIONS” carefully.
WARNING:
Compressors used on board boats can be certified via a R.I.Na (Registro Navale Italiano) test; this test
should be explicitly requested at the time of order.
IMPORTANT:
5.3.1 - POSITIONING
5 - HANDLING AND INSTALLATION
5.1 - UNPACKING
The
MCH-36
compressor is sent fully assembled,
but with the supplied flex hoses separate.
The compressor is packed in a cardboard box; the
latter is placed on a europallet to simplify handling
and transport.
The box containing the compressor must be moved
according to the instructions shown on the box itself.
The machine is supplied with the following as stan-
dard:
- 4 refill hoses, each 1200 mm long with tap;
- use and maintenance manual
- appendix to the use and maintenance manual
(Safety standards)
- Canned lubricating oil (5 litres)