Cap.6 _ Using the compressor
pag.
37
Use and maintenance manual
MCH-36
6.3.6 - MANUAL CONDENSATE DISCHARGE PUSHBUTTON
Pressing the manual condensate discharge button
(
6
) drains the condensate accumulated in the collec-
tor during use of the compressor.
To discharge the condensate see section “7.10
Condensate discharge”.
6.3.7 - CABINET INTERIOR / COOLING AIR TEMPERATURE
The cabinet interior temperature display (
7
)
indicates the temperature in °C inside the
compressor cabinet.
The temperature is set by the compressor
manufacturer.
The temperature may only be reset after obtaining
authorisation from AEROTECNICA COLTRI S.r.l.
This task must only be carried out by qualified
personnel.
6.3.8 - HOUR COUNTER
The hour counter (
8
) indicates the hours of effective
compressor operation: use this information to
observe maintenance schedules.
6.3.9 - LUBRICATING OIL CIRCUIT PRESSURE GAUGE
The gauge (
9
) indicates the pressure inside the
lubricating oil circuit.
If pressure is less than 1 bar check: oil level, oil
filter, oil viscosity.
If pressure is higher than 4 bar there is an
obstruction along the circuit; change the oil filter and
restart the machine. If pressure is still high contact
AEROTECNICA COLTRI S.r.l.
Compressor oil pressures are as follows:
- 4 bar cold
- 1.5 bar working pressure
- 1 bar minimum pressure
Temperature parameters must not be changed without prior authorisation from
AEROTECNICA COLTRI S.r.l.: doing so will render the warranty null and void (where still
valid).