Cap.6 _ Using the compressor
pag.
38
Use and maintenance manual
MCH-36
6.3.10 - 1st STAGE PRESSURE GAUGE
The gauge (
10
) indicates the pressure inside the 1st
compression stage.
If pressure is not between 3 bar (45 PSI) and 4 bar
(60 PSI) switch off the compressor and contact
AEROTECNICA COLTRI S.r.l.
6.3.11 - 2nd STAGE PRESSURE GAUGE
The gauge (
11
) indicates the pressure inside the 2nd
compression stage.
If pressure is not between 16 bar (230 PSI) and 20
bar (290 PSI)switch off the compressor and contact
AEROTECNICA COLTRI S.r.l.
6.3.12 - 3rd STAGE PRESSURE GAUGE
The gauge (
12
) indicates the pressure inside the 3rd
compression stage.
If pressure is not between 65 bar (940 PSI) and 80
bar (1200 PSI) switch off the compressor and
contact AEROTECNICA COLTRI S.r.l.
6.3.13 - WORKING PRESSURE GAUGE
The gauge (
13
) indicates air pressure as it exits the
compressor.
If the compressor fails to reach the pressure set on
the pressure switch, switch off the compressor and
contact AEROTECNICA COLTRI S.r.l.
Working pressure:
225 bar - 3200 PSI
330 bar - 4700 PSI
13
12
11
10