Cap.6 _ Using the compressor
pag.
41
Use and maintenance manual
MCH-36
6.4.2 - AUTOMATIC CONDENSATE DISCHARGE
The condensate gathered in the container (
d
) must
be drained as described below every 5 working
hours of the compressor.
Insert the condensate drain pipe (
a
) in a collection
can (
b
) and open the drain tap (
c
).
The release of vaporised water with lubricating oil
during bottle refill is normal: the quantity depends on
the level of humidity in the air.
The condensate must be disposed of as per the
instructions shown in paragraph “9.1 Waste dispo-
sal”.
c
a
b
The available bottle refill connectors are:
6.5 - BOTTLE REFILL
INT
DIN230
DIN300USA
DIN300
ITALIAN CONNECTOR FOR
SELF-PROTECTING
SCBA
During bottle refill those not involved in the refill procedure must maintain a safety distance
of at least 3 metres. Also, it is forbidden to disconnect the hoses from the fittings or the refill
tap while the machine is under pressure.
During refill the operator must be in the work area (see “4.1.7 Noise level”).
It is advisable, during the bottle refill phase, to submerge the bottles in cold water so as to reduce the
drop in pressure that accompanies cooling of the bottle.
IMPORTANT:
WARNING:
a
d
c