9. ANOMALIES AND FAULTS
Type
Description
The product doesn’t start
Ensure that the product is properly connected to the mains.
Ensure that the ON/OFF switch (I/O) is in ON (I) position.
The product properly starts but doesn’t
get any signal from the remote control
Ensure that the remote control is including the battery.
Ensure that the battery in the remote control is charged.
The commands re received only by the MASTER unit of the system, make sure
to send the commands to the right unit.
Ensure that the dip switches are properly set (MASTER).
The product properly starts, gets
signals from the remote control but
the impeller doesn’t turn
Need to wait 40 seconds for the automatic shutter starts opening
Ensure that the product is not in surveillance mode
Ensure that the impeller is not obstructed
The product doesn’t get any signal
from the remote control and the red
led flashes
Perform maintenance and filter reset as indicated in the manual.
Ensure that the remote control is including the battery.
Ensure that the battery in the remote control is charged.
The product runs only in extraction
and the red led is ON
Raise the threshold of the hygrostat with H button.
No communication between MASTER
and SLAVE units
Ensure the proper connection among the units.
Ensure that the dip switches are properly set.
If the problem detected is different from those listed above or whether the
problem is not solved after following the indications, need to contact an
authorized service center.
10. MAINTENANCE
Every 3000 working hours the indicator lights up on the MASTER unit to alert that maintenance
on the products is required.
All the units will continue to run according to the preset function without possibility to change
it until the maintenance operations are carried out.
Once maintenance is performed, press the button FILTER (
F
) on the remote control to reset
the alarm.
Advisable to replace the filters when becoming worn thus compromising the proper air filtration
and their efficiency, or at least within 2 years.
Contact your local retailer/distributor to get a filter kit replacement.
All the maintenance operations are intended for qualified personnel only.
Make sure that the network connection in the room is disconnected before
performing maintenance operation.
WARNING
WARNING