19
Keypad - Button
Figure 20
Button
Function
Down
Scroll down through a list.
Set
Press to accept a setting.
UP
Scroll up through a list.
Regenerate
Starts a regeneration.
Regeneration Modes
The WC300 controller can be regenerated either automatically or
manually. During a regeneration, the total time remaining of the
regeneration will be displayed on the controller. The current cycle
is shown in the lower left of the display.
To Initiate a Manual Regeneration:
• Press REGEN once for delayed regeneration. System will
regenerate at next set regen time (2:00 AM).
• A flashing regen (recycle) symbol will be displayed.
• Press and hold REGEN for 5 seconds to initiate immediate
manual regeneration. A solid regen symbol will be
displayed.
• After immediate regeneration has begun, press REGEN
again to initiate a second manual regeneration. A flashing
"x2" symbol indicates the second regeneration will start at
the time of regeneration. Press and hold REGEN to turn on
the second regeneration immediately following the current
regeneration. The double regeneration is indicated by the
"x2" symbol being on steady.
During a Regeneration:
• A "C#" is displayed to show current cycle.
• Total regen time remaining is displayed on screen.
• Press and hold SET to show current cycle time remaining.
To Advance Regeneration Cycles:
• Press and hold SET - showing current cycle time.
• Simultaneously press SET and UP to advance on cycle. An
hourglass will display while cam is advancing.
• When cam reaches next cycle, "C2” will be displayed.
• Repeat SET and UP to advance through each cycle.
• Press and hold SET and UP for 5 seconds to cancel regen.
• Hourglass will flash once canceled
• Camshaft will advance to home – may take 1 to 2 minutes.
Time & Day
Regen Time & Day
Salt
C
Capacity
Hardness
MIN
x2
SU
MO
TU
WE
TH
FR
SA
DAYS
Figure 21
Regeneration Cycles:
• C1 – Backwash
• C2 – Regeneration Draw/Slow Rinse
• C3 – Slow Rinse
• C4 – System Pause (to re-pressurize tank)
• C5 – Fast Rinse cycle 1
• C6 – Backwash cycle 2
• C7 – Fast Rinse cycle 2
• C8 – Brine Refill
Total regen time remaining
1
4
2
3
Summary of Contents for Origins WC300
Page 1: ...Operation Manual 00947 1821 EA 03671...
Page 33: ...Manuel d utilisation 00947 1821 EA 03671 A D O U C I S S E U R D E AU WC300...
Page 66: ...66...
Page 67: ...67...