SPECIFICATIONS 

Model: 

       

Rated 

Voltage: 

     

 

Rated 

Frequency: 

    

 

Rated 

Power: 

      

  

Rated 

Airflow: 

     

 

 
CADR value (CFM) (0.583*m3/h=1cfm) 

   

Air Purification Efficiency (PM 2.5)*

   

Coverage 

Area 

     

 

Weight 

       

 

Dimensions 

      

 

Water 

Tank 

Capacity 

    

 

Maximum Humidification Output

AP03

120VAC

       

60Hz

       

Air Purifier

: 35 watts

Humidifier

: 18 watts

124 cfm

5,650 ft3 per hour (94 CFM)

99%

Up to 400 sq. ft.

13.8 lbs.

13.7”L x 12.24”W x 12.87”H

1 gallon

2 gallons per 24 hours

Each of the performance parameters in the above chart is measured before the machine leaves the factory according to the 
effective GB/T 18801, GB4706.1 and GB4706.45.

*PM 2.5 defined: Particulate matter, or PM, is the term for particles found in the air, including dust, dirt, soot, smoke, 
and liquid droplets. Particles can be suspended in the air for long periods of time. Some particles are large or dark 
enough to be seen as soot or smoke. Others are so small that individually they can only be detected with an electron 
microscope.

Particles that measure less than 10 micrometers in diameter (PM10) pose a health concern because they can be inhaled 
into and accumulate in the respiratory system. Particles less than 2.5 micrometers in diameter (PM 2.5) are referred to 
as “fine” particles and are believed to pose the greatest health risks. Because of their small size (approximately 1/30th 
the average width of a human hair), fine particles can lodge deeply into the lungs.**

**Excerpt borrowed from www.epa.gov/particle-pollution-designations/learn-about-particle-pollution-

designations#process. Learn more about PM 2.5 from the United States EPA.

Summary of Contents for PowerPure AP03

Page 1: ...Aerus PowerPure AP03 HEPA Air Purifier Ultrasonic Humidifier CAUTION READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION ...

Page 2: ...ctions for the unit If you have any questions concerning this product contact Aerus Customer Service by calling toll free 1 888 764 0693 or via email at support aerusonline com TABLE OF CONTENTS Introduction 2 Product Specifications 3 Important Safety Instructions 4 Operational Placement Parts Diagram 5 Getting Started 6 7 Control Panel Product Operation 8 Features 9 Odor Sensor 10 Product Mainten...

Page 3: ...g dust dirt soot smoke and liquid droplets Particles can be suspended in the air for long periods of time Some particles are large or dark enough to be seen as soot or smoke Others are so small that individually they can only be detected with an electron microscope Particles that measure less than 10 micrometers in diameter PM10 pose a health concern because they can be inhaled into and accumulate...

Page 4: ...formance prevent tipping and damage to flooring or furniture Make sure there is at least 8 inches between the air inlet on the bottom of the air purifier and objects within the room Do not wring pinch bend or twist the power cord Do not drag the power cord when it is disconnected from the wall outlet Never use the air purifier if there is damage to the unit or the power cord To avoid electrical sh...

Page 5: ...e between the air purifier and the wall to allow the purified air to thoroughly circulate through the room Please avoid placing the AP03 in front of a centralized heating return or another type of heating source Choose a location that is close to a power outlet for easy connection to the electrical source the power cord length is 5 9 ft PARTS DIAGRAM FRONT PANEL PRE FILTER ACTIVATED CARBON FILTER ...

Page 6: ...on Filter from the unit Completely remove all of the packaging from each filter Step 3 Insert the filters back into the filter cavity in this order 1 Insert the Activated Carbon Filter front side facing out 2 Insert the HEPA filter front side facing out 3 Insert the Pre Filter by bowing slightly and inserting Tabs into one side and then into the other side Step 4 Reinsert and close the front panel...

Page 7: ...ce Step 1 Put your finger inside the lifting yoke and lift up the water tank to remove Step 2 Turn the water tank upside down and remove the cap by turning counter clockwise Step 3 Fill the water tank with water Step 4 Replace the cap and rotate clockwise to tighten making sure it is tight to ensure a waterproof seal Step 5 Carefully place the water tank back onto the unit making sure the inner ta...

Page 8: ...Use this button to toggle between Low High or Off When activated the humidifier always starts in high humidification mode NOTE When the tank is empty the HUMIDIFICATION button will blink three times and turn off FILTER RESET BUTTON Press and hold the FILTER RESET button for three seconds to turn off and reset the Filter Reset indicator AFTER the filters have been replaced Replace the HEPA Filter a...

Page 9: ...e 1 for the removal of large course particles High Efficiency HEPA Filter stage 2 for the removal of microscopic particles Activated Carbon Filter stage 3 for the removal of contaminants such as VOCs and other common household odors Ultrasonic Humidifier The appliance features an ultrasonic humidifier that enables you to achieve proper humidity levels in your home It will humidify spaces up to 400...

Page 10: ...the appliance As part of general maintenance the Pre Filter should be evaluated and cleaned every two months if there is a build up covering the filter HEPA Filter Replace approximately every 6 months based upon a run time of 24 hours per day The Filter Reset light will illuminate red prompting you to change the HEPA Filter Active Carbon Filter Replace approximately every 6 months based upon a run...

Page 11: ...nit on Decreased particulate or odor removal 1 HEPA and Activated Carbon Filter are not installed properly for correct airflow 2 Activated Carbon Filter has expired and needs to be replaced 3 Inspect filters to ensure there is no blockage of foreign matter 1 Ensure the HEPA and Activated Carbon Filters are inserted correctly and facing the correct direction within the unit 2 Replace the Activated ...

Page 12: ...placement unit at the company s option WE reserve the right to inspect and or require conformation of installation method WHAT IS NOT COVERED BY THIS WARRANTY Not for commercial use Ordinary wear and tear shall not be considered a defect in workmanship or material These warranties do not apply for loss or damage caused by accident fire abuse misuse improper installation leaking modification misapp...

Page 13: ... may not apply to you If any provision of this warranty or part thereof is held by a court of competent jurisdiction to be invalid illegal or unenforceable the validity legality and enforceability of the remaining provisions or parts thereof will not in any way be affected or impaired within the jurisdiction of that court This entire warranty shall continue to be valid legal and enforceable in any...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...ance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea...

Reviews: