G-Model Inverter Heat Pump
3
2. Attention
a. Please read the following instructions before installation, use and maintenance.
b. Installation must be done by professional staff only in accordance with this manual.
c. Leakage test must be performed after installation.
d. Please don’t stack substances close or on the heat pump, which will reduce efficiency or damage the
heat pump.
e. If a repair is required, please contact the nearest after-sales service center. The repair process must
be strictly in accordance with the manual. All repair practice by non-professional is prohibited.
f.
Don’t use or stock combustible gas or liquid l block air flow near inlet or outlet area, otherwise the
efficiency of the heat pump will be reduced, or the unit could even stop working.
g. Set proper temperature in order to get comfortable water temperature to avoid overheating or
overcooling.
h. In order to optimize the heating effect, please ensure that the pipes between the swimming pool and
the heat pump are insulated to reduce heat loss. It is also recommended that a suitable pool cover
be installed on the pool at all times when the pool is not in use.
i.
For maximum efficiency, the connecting pipes between the pool filter and the heat pump should be
insulated and as short as practically possible: if over 10m extra thick insulation on the waterpipe is
recommended.
j.
Do not accelerate the defrosting process by any means other than recommended by manufacturer,
3. Safety
k. Please keep the main power supply switch far away from the children.
l.
When a power cut happens during operating, and later the power is restored, the heat pump will
m. start up.
n. During stormy weather switch off the main power supply and disconnect the power to the heat pump
to prevent any damage that could be caused by lightning.
o. A safety inspection must be carried out before the maintenance or repair of heat pumps with R32 gas
in order to minimize the risk for fire.
p. Installation and repairs should be carried well-ventilated areas. No ignition sources (sparks or flames)
are allowed near the unit while it is in operation.
q. If there is any R32 gas leak during the installation process, stop all operations immediately and call
the service center.
Summary of Contents for PROTEAM G-Silent G108
Page 26: ...G Model Inverter Heat Pump J Wi Fi operation Inverter Heat Pump 24 ...
Page 27: ...G Model Inverter Heat Pump 25 ...
Page 28: ...G Model Inverter Heat Pump 26 ...
Page 29: ...G Model Inverter Heat Pump 27 ...
Page 30: ...G Model Inverter Heat Pump 28 ...
Page 31: ...G Model Inverter Heat Pump 29 ...