ROBOTAPE 50 ME - LH
4.6. RECOMMENDATIONS FOR CONNECTIONS
|
Important
The connections must be made in accordance with the specifications supplied by the manufacturer in the
enclosed diagrams.
The person authorized to carry out said operation must posses the skills and experience acquired and
acknowledged in the specific sector, must perform the connection workmanlike and keep into account all the
statutory and legislation requirements.
Once the connection has been completed, before commissioning the machinery, it is necessary to perform an
overall control to verify if said requirements have been complied with.
4.7. ELECTRICAL CONNECTION
Proceed as follows for electrical connections.
1.
Check that the mains voltage
(V)
and
frequency
(hz)
correspond to those of
the machine (see identification plate and
wiring diagram).
2.
Turn main switch
(P)
to pos.
O
.
3.
Connect the power cord to the outlet
(A)
,
as illustrated, according to the network
mains.
4.
The earth wire (yellow and green) must
be connected to its earth terminal
PE
.
5.
Turn main switch
(P)
to pos.
1
.
6.
Start the electric motor and check that
rotation direction is that indicated on the
plate.
|
Important
If the direction is wrong, deactivate the
main electrical knife and invert the
phase cables.
25/43