Mounting Instructions EN
◼
SE-Power FS
◼
01.06.2022
◼
V4.4
21
–50
3.3
Motor connection [X6]
Table 7:
Technical data: Motor connection data [X6]
Type
SE-Power FS
1kVA
SE-Power FS
3kVA
SE-Power FS
6kVA
Specifications for operation with
:
1x 230 VAC [±
10%], 50 Hz
3x 400 VAC [± 10%], 50 Hz
Output power
1,0 kVA
3,0 kVA
6,0 kVA
Max. output power for 5 s
2,0 kVA
3,0 kVA
12,0 kVA
Output current
5 A
eff
5 A
eff
10 A
eff
Max. output current for 5 s
10 A
eff
10 A
eff
(15 A
eff
for 2 s)
20 A
eff
Max. output current for 0.5s
20 A
eff
20 A
eff
40 A
eff
Current derating from
12 kHz
12,5 kHz
5 kHz
Max. clock frequency
Ca. 20 kHz
4 … 16 kHz
3.4
I/O interface [X1]
Table 8:
Technical Data: digital inputs and outputs [X1]
Digital inputs / outputs
Values
Signal level
24V (8V...30V) active high, conform with EN 1131-2
Logical inputs general
DIN0
DIN1
DIN2
DIN3
Bit 0 \
Bit 1, \ Target selection for positioning
Bit 2, / 16 targets selectable from target table
Bit 3 /
DIN4
Control input stage enable at High
DIN5
Controller enable at high signal, ack. error with falling edge
DIN6
End switch input 0
If hardware limit switches are
required, a parameter file must
be requested in accordance with
specification Afag.
DIN7
End switch input 1
DIN8
Homing switch
DIN9
Control signal Start positioning
DIN AIN1
Start homing
DIN AIN2
Set-up mode (low active)
0V
➔
slow
24V
➔
normal operation
Logic outputs general
Galvanically separated, 24V (8V...30V) active high
DOUT0
Servo controller operational
24 V, max. 100 mA
DOUT1
Homing position valid
24 V, max. 100 mA
DOUT2
In position
24 V, max. 100 mA
DOUT3
Remaining distance
24 V, max. 100 mA
DOUT4 [X6]
Holding brake
24 V, max. 1 A