38
–50
Mounting Instructions EN
◼
SE-Power FS
◼
01.06.2022
◼
V4.4
Connection: Motor [X6]
Table 14:
Pin assignment [X6] SE-Power FS 1kVA
Pin No.
Denomination Value
Specification
1
BR-
0V brake
Holding brake (motor), signal
level dependent on switch status,
high side / low side switch
2
BR+
24V brake
3
PE
PE
Connection for inner shield
(holding brake + temperature
sensor)
4
MT-
GND
Motor temperature sensor, N.C.
and N.O. contact, PTC, NTC
5
MT+
+5V / 5mA
6
PE
PE
Motor ground conductor
7
W
0...270V
eff
0...5 A
eff
0...1000Hz
Connection of the three motor
phases
8
V
9
U
Table 15:
Pin assignment [X6] SE-Power FS 3kVA und 6kVA
Pin No.
Denomination Value
Specification
1
BR-
0V brake
Holding brake (motor), signal
level dependent on switch status,
high side / low side switch
2
BR+
24V brake
3
PE
PE
Connection for inner shield
(holding brake + temperature
sensor)
4
MT-
GND
Motor temperature sensor, N.C.
and N.O. contact, PTC, NTC
5
MT+
+5V / 5mA
6
PE
PE
Motor ground conductor
7
W
0...360V
eff
0...5 A
eff
SE-Power FS 3kVA
0...10 A
eff
SE-Power FS
6kVA
0...1000Hz
Connection of the three motor
phases
8
V
9
U
The outer cable shield of the motor cable must also be placed flat on the
mounting plate of the controller housing to shield terminal SK14.