Maintenance and repair
58 – 64
Assembly instructions EN
CS 16 - CS 20
Date 01.06.2021
Version 6.0
When using the compact slides in an ionized air environment (e.g. for high-
voltage processors/coronization), coat open guides and piston rods with
grease to prevent rust formation!
Afag standard lubrication:
- Staburax NBU8EP (flat guides)
- Blasolube 301 (piston rods)
9.3.3 Further maintenance
Further maintenance is not required, if the ambient conditions listed below are
complied with:
Clean working area
No use of splash water
No abrasive or process dust and vapours
Climate and temperature as specified in the technical data
Spare and wear parts lists, repairs
9.4.1 General notes
Afag Automation AG offers a reliable repair service. Defective modules can be
sent to Afag for warranty repair within the warranty period.
After the warranty period has expired, the customer can replace or repair
defective modules or wear parts himself or send them to the Afag repair service.
Please note that Afag does not assume any warranty for modules that have
not been replaced or repaired by Afag!
9.4.2 Safety instructions
CAUTION
Risk of injury when removing the compact slide due to uncontrolled
movements!
When disassembling the compact slides from a system, there is a danger of
uncontrolled movements.
Disconnect the media supply (pneumatics) before removing the modules!
Disassembling should only be carried out by qualified personnel!
Bleed and deactivate the equipment before removing the compact slide!
Before removing the compact slide, switch off the control unit and secure it
against being switched on again!