Maintenance and repair
56 – 64
Assembly instructions EN
CS 16 - CS 20
Date 01.06.2021
Version 6.0
Maintenance activities and maintenance intervals
9.3.1 Overview of the maintenance points
Fig. 28
Maintenance points Compact Slide (CS 16 and CS 20)
No. Maintenance point
Maintenance work
Interval
System
[On/Off]
Remarks
1
Compact Slide
Cleaning
As required
[Off]
-
Clean the compact slide with a dry, lint-free cloth.
- do not spray with water
- Do not use aggressive cleaning agents.
2
Shock absorber*
Check functioning
Monthly
[On]
Check function of shock absorbers, replace if necessary
replacing after max. 5 million load cycles
3
Compact Slide
Check
Monthly
[On]
-
Acoustic control for unusual noise generation
Incorrectly adjusted, missing or defective shock absorbers impair the function
of the module and can lead to its destruction!
*Shock absorbers and stop screws must be checked regularly for correct
function and replaced if necessary. We recommend replacing the shock
absorbers after max. 5 million load cycles.