EU-20-OI-v-1.2 gb. 28.07.14.docx
29
4.2 Regular maintenance
Maintenance
intervall
Maintenance work
If necessary
Cleaning of the module with a dry, lint-free cloth.
The module must not be washed down any aggressive clean-
ing agents are allowed to use.
Table 4: Maintenance work
4.3 Further maintenance
Under the ambient conditions mentioned below the EU-20 electric gripper does not
require any further maintenance:
-
clean workshop atmosphere
-
no splash water
-
no friction dust or dust from processing
-
climate and temperature according to the technical data.
4.4 Troubleshooting
WARNING
The gripper fingers are moved by the electric control. If the
gripper fingers cannot move freely there is danger of injuries
and bruises near the add-ons.
Observe the Montage Instructions of the system into which the
EU-20 electric gripper was incorporated.
WARNING
Due to the decentral controller the operator of the EU-20 electric
gripper needs not to be near the product so that third persons
might be endangered by the gripper operation.
Always switch off the control and protect it from being switched
on again unintentionally when you work on the EU-20 electric
gripper. The signals of the control system may cause uninten-
tional movements of the module which may lead to personal
injuries.