Page 46
22.10.2019
R01.43
Import/Export of Configurations (4)
A new window opens in which the parameter records saved in the computer are
loaded. The current parameter set can also be stored locally. Only the current aflex
parameters are exported or overwritten during import. This must be observed.
INSTRUCTION
Import Configuration:
The current parameters are overwritten with the imported ones.
The imported parameters are not automatically saved as a con-
figuration. If desired, the current parameters must then be stored
manually.
Configuration number Selection (5)
From user level "advanced" visible. Select the configuration number which should be
saved.
Configuration name Input (6)
From user level "advanced" visible. Entry of the configuration name should be saved.
Maximum of 21 characters.
Save configuration (7)
From user level "advanced" visible. Saves the current aflex parameters under the se-
lected configuration number (5) and the entered configuration name (6).
Delete configuration (8)
Visible from user level "advanced". Deletes the selected configuration (1). Configura-
tion numbers 1 & 2 can not be deleted.
4.5.3 Backlight
If there is an aflex Backlight Node connected the slider
adjust its light intensity. The Serial number of the back-
light Node is displayed. Otherwise the Slider adjust the
ControlUnit power output.
The control unit has a 24V PWM power output. The
PWM duty cycle is controlled by a slider from 0-100%. The background lighting of the
aflex is connected to this power output. This slider is shown in the figure below.
Figure 32: Control unit Power Output